    TEXT VERSION OF SLIDE:

    Title: (j) Hygiene Facility and Practices - Class I Jobs Involving > 25 Linear or 10 Square Feet of TSI or Surfacing ACM and PACM
    Type: Text Slide
    Content:
    • Decontamination area must be established adjacent and connected to the regulated area
      • Equipment room
      • Shower area (adjacent to the equipment room and the clean room, where feasible)
      • Clean change room
    • Employees must enter the regulated area through the decontamination area
      • Equipment room to Shower area to Clean room
    • For all Class I work: Lunch areas must be provided in which the airborne asbestos concentration is below the PELs