General Description

Synonyms: Carbonyl chloride; Carbon oxychloride; Chloroformyl chloride

OSHA IMIS Code Number: 2070

Chemical Abstracts Service (CAS) Registry Number: 75-44-5

NIOSH Registry of Toxic Effects of Chemical Substances (RTECS) Identification Number: SY5600000

Department of Transportation Regulation Number (49 CFR 172.101) and Guide: 1076 125

NIOSH Pocket Guide to Chemical Hazards, Phosgene: chemical description, physical properties, potentially hazardous incompatibilities, and more

Exposure Limits

OSHA Permissible Exposure Limit (PEL):

General Industry: 29 CFR 1910.1000 Z-1 Table -- 0.1 ppm, 0.4 mg/m3 TWA

Maritime: 29 CFR 1915.1000 Table Z-Shipyards -- 0.1 ppm, 0.4 mg/m3 TWA

American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV): 0.1 ppm, 0.4 mg/m3 TWA

National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL): 0.1 ppm, 0.4 mg/m3 TWA; 0.2 ppm, 0.8 mg/m3 Ceiling (15 Minutes)

Health Factors

Carcinogenic Classification:

Environmental Protection Agency (EPA): Group D, not classifiable as to human carcinogenicity

NIOSH Immediately Dangerous To Life or Health Concentration (IDLH): 2 ppm

Potential Symptoms: Eye irritation; dry burning throat, choking; vomiting; coughing, foamy bloody sputum, dyspnea, chest pain; pulmonary edema, cyanosis; skin redness, burns; frostbite (liquid form)

Health Effects: Acute lung damage/edema (HE11); Cumulative lung damage-Emphysema, fibrosis (HE10); Irritation-Eyes, Skin---Marked (HE14)

Affected Organs: Respiratory system, skin, eyes

Literature Basis:

  • International Chemical Safety Cards (WHO/IPCS/ILO): Phosgene.
  • (symptoms and IDLH)
    US EPA Technology Transfer Network Air Toxics Website: Technology Transfer Network Air Toxics Website: Phosgene.

Date Last Revised: 07/09/2003

Monitoring Methods used by OSHA

Primary Laboratory Sampling/Analytical Method (SLC1):

  • sampling media: Coated XAD-2 Tube (150/75 mg sections, 20/60 mesh) Coated with 10% (w/w) 2-(Hydroxymethyl)piperidine
    analytical solvent: Toluene
    maximum volume: 240 Liters
    maximum flow rate: 1.0 L/min
    current analytical method: Gas Chromatography; GC/NPD
    method reference: OSHA Analytical Method (OSHA 61)
    method classification: Fully Validated
    note: OSHA personnel may obtain sampling tube from the Salt Lake Tecnical Center. When relative humidity at sampling site is low, reduce maximum sample size to 120 Liters and sampling rate to 0.5 L/min.

On-Site Sampling Techniques/Methods:

  • device: Detector Tube
    manufacturer: AUER/MSA
    model/type: Phosgene-0.1, MSA P/N 803949, AUER P/N 5085-854
    sampling information: follow manufacturer's instructions
    upper measurement limit: 20 ppm
    detection limit: approx. 0.1 ppm
    overall uncertainty: unknown
    method reference: on-site air secondary (manufacturer)

  • device: Detector Tube
    manufacturer: Dräger
    model/type: Phosgene 0.02/a, order no. 81 01521
    sampling information: 20 or 40 strokes
    upper measurement limit: 1 ppm
    detection limit: approx. 0.01 ppm
    overall uncertainty: 16%
    method reference: on-site air secondary (manufacturer)

  • device: Detector Tube
    manufacturer: Dräger
    model/type: Phosgene 0.05/a, order no. CH 19401
    sampling information: 1 to 33 strokes
    upper measurement limit: 1.5 ppm
    detection limit: approx. 0.04 ppm
    overall uncertainty: 32%
    method reference: on-site air secondary (manufacturer)

  • device: Detector Tube
    manufacturer: Dräger
    model/type: Phosgene 0.25/a, order no. CH 28301
    sampling information: 5 strokes
    upper measurement limit: 5 ppm
    detection limit: approx. 0.1 ppm
    overall uncertainty: 25%
    method reference: on-site air secondary (manufacturer)

  • device: Detector Tube
    manufacturer: Gastec
    model/type: 16
    sampling information: 1 to 10 strokes
    upper measurement limit: 20 ppm
    detection limit: 0.01 ppm
    overall uncertainty: 16% for 0.1 to 1 ppm, 8% for 1 to 5 ppm
    method reference: on-site air secondary (manufacturer)

  • device: Detector Tube
    manufacturer: Matheson-Kitagawa
    model/type: 8014-146S
    sampling information: follow manufacturer's instructions
    upper measurement limit: 20 ppm
    detection limit: approx. 0.1 ppm
    overall uncertainty: unknown
    method reference: on-site air secondary (manufacturer)