Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 548019.015 - Southeast Texas Industries, Inc.

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 548019.015
Report ID: 0626700
Date Opened: 07/26/2012

Site Address:
Southeast Texas Industries, Inc.
635 Old Hwy 90 West
Vidor, TX 77662

Mailing Address:
635 Old Hwy 90 West, Vidor, TX 77662

Union Status: NonUnion

SIC:

NAICS: 333132/Oil and Gas Field Machinery and Equipment Manufacturing


Inspection Type: Fat/Cat

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/24/2012

Emphasis: L:Fabmetsh

Case Closed: 11/20/2012


Related Activity
Type Activity Nr Safety Health
Accident 468230
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 1 3 4
Initial Penalty $24,000 $0 $0 $0 $0 $24,000
Current Penalty $1,800 $0 $0 $12,600 $0 $14,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100304 B03 II A 10/29/2012 11/28/2012 $4,200 $7,000 $0 I - Informal Settlement  
2. 01002 Other 19100305 A02 X 10/29/2012 10/30/2012 $4,200 $7,000 $0 I - Informal Settlement  
3. 01003 Other 19100305 G02 III 10/29/2012 10/30/2012 $4,200 $7,000 $0 I - Informal Settlement  
4. 01004 Serious 19100334 A02 I 10/29/2012 10/30/2012 $1,800 $3,000 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 24075.015
Event: 07/25/2012
Employee Contacts Electrified Toolbox And Is Electrocuted

At approximately 2:10 p.m. on July 25, 2012, Employee #1 was fitting structural steel that would eventually be used to build a land based oil rig. A 120 volt extension cord, used to power the employee's grinder and fan, was lying across a welder's ground clamp. The ground clamp became hot and melted the insulation on the extension cord. The hot black conductor contacted the ground clamp and energized the equipment being welded and anything that was connected to the grounded piece of equipment. A flat bar was on the floor of the shop. The piece of equipment which employee was working on was electrically connected by the piece of flat bar. The metal toolbox was conductive and electrified. Employee #1 went to get his toolbox and was electrocuted when he touched the electrified toolbox.

Keywords: Electric Cord, Electrical, Electrocuted, Oil Rig

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 548019.015 40 M Fatality Construction trades, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.