Inspection Detail
Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.
Inspection: 1602901.015 - Hvfg, Llc
Inspection Information - Office: Albany
Site Address:
Hvfg, Llc
22 County Road 183c
Bethel, NY 12720
Mailing Address:
80 Brooks Road, Ferndale, NY 12734
Union Status: NonUnion
SIC:
NAICS: 311999/All Other Miscellaneous Food Manufacturing
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/20/2022
Emphasis:
Case Closed:
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1907974 | ||
Inspection | 1603578 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 6 | 1 | 7 | |||
Current Violations | 6 | 1 | 7 | |||
Initial Penalty | $65,262 | $0 | $22,376 | $0 | $0 | $87,638 |
Current Penalty | $65,262 | $0 | $22,376 | $0 | $0 | $87,638 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100146 C01 | 12/12/2022 | 12/30/2022 | $9,324 | $9,324 | $0 | 01/10/2023 | C - Contested | |
2. | 01002 | Serious | 19100146 C02 | 12/12/2022 | 12/30/2022 | $13,052 | $13,052 | $0 | 01/10/2023 | C - Contested | |
3. | 01003A | Serious | 19100146 C04 | 12/12/2022 | 12/30/2022 | $13,052 | $13,052 | $0 | 01/10/2023 | C - Contested | |
4. | 01003B | Serious | 19100146 D03 | 12/12/2022 | 12/30/2022 | $0 | $0 | $0 | 01/10/2023 | C - Contested | |
5. | 01003C | Serious | 19100146 D06 | 12/12/2022 | 12/30/2022 | $0 | $0 | $0 | 01/10/2023 | C - Contested | |
6. | 01003D | Serious | 19100146 D09 | 12/12/2022 | 12/30/2022 | $0 | $0 | $0 | 01/10/2023 | C - Contested | |
7. | 01003E | Serious | 19100146 G01 | 12/12/2022 | 12/30/2022 | $0 | $0 | $0 | 01/10/2023 | C - Contested | |
8. | 01004 | Serious | 19100146 D04 IX | 12/12/2022 | 12/30/2022 | $13,052 | $13,052 | $0 | 01/10/2023 | C - Contested | |
9. | 01005 | Serious | 19100147 C04 I | 12/12/2022 | 12/30/2022 | $7,458 | $7,458 | $0 | 01/10/2023 | C - Contested | |
10. | 01006 | Serious | 19100147 C06 I | 12/12/2022 | 12/30/2022 | $9,324 | $9,324 | $0 | 01/10/2023 | C - Contested | |
11. | 02001 | Repeat | 19100147 C07 I | 12/12/2022 | 12/30/2022 | $22,376 | $22,376 | $0 | 01/10/2023 | C - Contested |
Investigation Summary
At 4:45 p.m. on June 19, 2022, an employee was replacing a submersible sewage pu mp located in a sump pit. The sump pit was floor-level and located in the corne r of a raw processing room. The sump pit was 2 feet in diameter and 6 feet deep, and was approximately 2/3 full of wastewater. The employee was using Channeloc k pliers to reconnect a 2 inch diameter polyvinyl chloride (PVC) outlet pipe to the pump, when he dropped the pliers into the sump pit. The employee tried to r etrieve the pliers and fell into the sump pit head first. No one witnessed the i ncident, as the employee was working alone. The employee was found killed by dro wning at a later time, submerged headfirst with his feet protruding from the sum p pit.
Keywords:drown, drowning, maintenance, pit, sewage, stuck, working alone
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 1602901.015 | Fatality | Kitchen workers, food preparation |