Violation Detail
Standard Cited: 19100146 D03 Permit-required confined spaces
Inspection Nr: 1602901.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 12/30/2022
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/12/2022
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0213100
Contest Date: 01/10/2023
Final Order:
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 01/10/2023 | $0.00 | 12/30/2022 | Serious | |
Penalty | Z: Issued | 12/12/2022 | $0.00 | 12/30/2022 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations: (a) At the worksite (White Lake Facility): On or about��6/19/22, where an employee removed and replaced the Goulds WS0511B submersible sewage pump(s)�in floor drain sump pit(s) in the Kettle Room and Raw Processing Room; a procedure was not implemented to ensure safe entry. (b) At the worksite (White Lake Facility): On or about 6/12/22, where an employee removed and replaced the Goulds WS0511B submersible sewage pump in floor drain sump pit in the Raw Processing Room; a procedure was not implemented to ensure safe entry.