Inspection Detail
Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.
Inspection: 1501977.015 - Sterling Bridge, Llc
Inspection Information - Office: Naperville
Site Address:
Sterling Bridge, Llc
1241 N. Ellis
Bensenville, IL 60106
Mailing Address:
1241 N. Ellis, Bensenville, IL 60106
Union Status: NonUnion
SIC:
NAICS: 333249
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/10/2021
Emphasis: N:Dustexpl
Close Case:
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1686013 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 6 | 1 | 7 | |||
Current Violations | 3 | 1 | 4 | |||
Initial Penalty | $54,612 | $0 | $0 | $1,366 | $0 | $55,978 |
Current Penalty | $40,959 | $0 | $0 | $0 | $0 | $40,959 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 05/10/2021 | 02/17/2023 | $13,653 | $9,557 | $0 | 05/12/2021 | F - Formal Settlement | |
2. | 01002 | Serious | 19100134 F02 | 05/10/2021 | 06/16/2021 | $8,192 | $8,192 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. |
3. | 01003 | Serious | 19100134 K01 | 05/10/2021 | 06/16/2021 | $8,192 | $8,192 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. |
4. | 01004 | Serious | 19100307 C | 05/10/2021 | 02/17/2023 | $13,653 | $9,557 | $0 | 05/12/2021 | F - Formal Settlement | |
5. | 01005A | Serious | 19101200 G02 II | 05/10/2021 | 02/17/2023 | $13,653 | $9,557 | $0 | 05/12/2021 | F - Formal Settlement | |
6. | 01005B | Serious | 19101200 G02 III | 05/10/2021 | 06/16/2021 | $0 | $0 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. |
7. | 01006A | Serious | 19101200 H01 | 05/10/2021 | 06/16/2021 | $9,557 | $9,557 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. |
8. | 01006B | Serious | 19101200 H02 II | 05/10/2021 | 06/16/2021 | $0 | $0 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. |
9. | 01006C | Serious | 19101200 H03 I | 05/10/2021 | 06/16/2021 | $0 | $0 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. |
10. | 01006D | Serious | 19101200 H03 II | 05/10/2021 | 06/16/2021 | $0 | $0 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. |
11. | 01006E | Serious | 19101200 H03 III | 05/10/2021 | 06/16/2021 | $0 | $0 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. |
12. | 02001 | Other | 19040040 A | 05/10/2021 | 06/16/2021 | $0 | $1,366 | $0 | 05/12/2021 | F - Formal Settlement |
Investigation Summary
At 4:30 p.m. on November 11, 2020, two employees were in the process of producin g batches of a chlorine dioxide generator inside a newly purchased mixer. Emplo yee #1 was killed in an explosion after closing the lid on the mixer to complete the mixing operations. Employee #2 was injured during the rescue attempt. The manufacturing room and the surrounding area sustained extensive damage.
Keywords:chlorine dioxide, electric generator, explosion, fire, mixer
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 1501977.015 | Hospitalized injury | ||||
2 | 1501977.015 | Fatality |