Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1434862.015 - Kik Custom Products

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 1434862.015
Report ID: 0626700
Date Opened: 10/01/2019

Site Address:
Kik Custom Products
2921 Corder Street
Houston, TX 77054

Mailing Address:
2921 Corder Street, Houston, TX 77054

Union Status: NonUnion

SIC:

NAICS: 325998/All Other Miscellaneous Chemical Product and Preparation Manufacturing


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/01/2019

Emphasis:

Case Closed: 04/11/2024


Related Activity
Type Activity Nr Safety Health
Referral 1503951 Yes Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $26,988 $0 $67,470 $0 $0 $94,458
Current Penalty $13,930 $0 $47,470 $0 $0 $61,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100147 C04 I 02/10/2020 04/24/2020 $13,494 $13,494 $0 I - Informal Settlement  
2. 01001B Serious 19100147 D06 02/10/2020 04/24/2020 $0 $0 $0 I - Informal Settlement  
3. 01002 Serious 19100151 C 02/10/2020 03/27/2020 $436 $13,494 $0 I - Informal Settlement  
4. 02001A Repeat 19100132 A 02/10/2020 04/24/2020 $47,470 $67,470 $0 I - Informal Settlement  
5. 02001B Repeat 19100132 D01 02/10/2020 03/27/2020 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 120343.015
Event: 09/28/2019
Employee Sustains Chemical Burns While Repairing Pipe Leak

At 8:45 a.m. on September 28, 2019, an employee was repairing a leak on overhead piping at a chemical manufacturing facility. While working, product containing 16.5% concentrated bleach came out of the pump side of the piping came out and splashed the employee. The employee sustained second degree burns on the right side of his body and third degree burns on his buttocks. The employee was hospitalized.

Keywords: Bleach, Burn, Buttocks, Chemical, Chemical Burn, Chemical Exposure, Leak, Pipe, Pump, Repair, Splashed

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1434862.015 54 M Hospitalized injury Millwrights
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.