Violation Detail
Standard Cited: 19100147 D06 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1434862.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 04/24/2020 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/10/2020
Nr Instances: 1
Nr Exposed: 14
Related Event Code (REC):
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 03/02/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/02/2020 | $0.00 | 04/24/2020 | Serious | |
Penalty | Z: Issued | 02/10/2020 | $0.00 | 03/27/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(6): Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment have been accomplished. On or about September 25, 2019, at the KIK Custom Products Processor Tank Farm in Houston, Texas; the employer failed to ensure that isolation and deenergization of the machine or equipment had been accomplished and verified prior to open the 16% concentrated bleach piping leading to the Unfiltered Tanks #1-2 & Bodyfeed Tank for leak repair.