Inspection Detail
Inspection: 1210448.015 - Rehau Automotive Llc
Inspection Information - Office: Birmingham Area Office
Site Address:
Rehau Automotive Llc
2424 Industrial Drive Sw
Cullman, AL 35055
Mailing Address:
2424 Industrial Drive Sw, Cullman, AL 35055
Union Status: NonUnion
SIC:
NAICS: 326199/All Other Plastics Product Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/09/2017
Emphasis:
Case Closed: 06/08/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1181308 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $12,314 | $0 | $0 | $0 | $0 | $12,314 |
| Current Penalty | $7,388 | $0 | $0 | $0 | $0 | $7,388 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100106 E09 I | 05/23/2017 | 06/19/2017 | $3,694 | $6,157 | $0 | I - Informal Settlement | ||
| 2. | 01002A | Serious | 19101200 H03 III | 05/23/2017 | 07/11/2017 | $3,694 | $6,157 | $0 | I - Informal Settlement | ||
| 3. | 01002B | Serious | 19101200 F06 I | 05/23/2017 | 07/11/2017 | $0 | $0 | $0 | I - Informal Settlement | ||
| 4. | 02001 | Other | 19100305 B01 II | 05/23/2017 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At 3:30 p.m. on February 7, 2017, an employee was participating in a meeting in a conference room that was adjacent to the facility laboratory where xylene was being used. During the meeting, the laboratory ventilation hood fan failed and xylene was released into the laboratory and migrated into surrounding areas. The employee, who had documented chemical sensitivity, displayed symptoms of overexposure. While emergency services were contacted, the employee was administered an epipen and was removed from the affected area. The employee was transported to a nearby hospital, where they were treated for hypoxemic respiratory failure and held overnight. The incident investigation reported that the laboratory had been conducting an 8 hour test, where xylene was being boiled that continued despite the exhaust fan in the laboratory hood failing.
Keywords: Allergic Reaction, Chemical, Equipment Failure, Toxic Fumes
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1210448.015 | 39 | F | Hospitalized injury | Purchasing agents and buyers n.e.c. |
Translate