Powered by GoogleTranslate

Inspection Detail

Inspection: 312447303 - Harrelson Utilities, Inc.

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 312447303
Report ID: 0453710
Date Opened: 08/26/2008

Site Address:
Harrelson Utilities, Inc.
Preserves At Amberly
Cary, NC 27519

Mailing Address:
1401 North Arendell Avenue Suite D, Zebulon, NC 27597

Union Status: NonUnion

SIC:1623

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/09/2009

Planning Guide: Health-Construction

Emphasis:

Case Closed: 12/22/2011


Related Activity
Type Activity Nr Safety Health
Accident 100359405
Referral 202867461 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 6
Current Violations 4 2 6
Initial Penalty $14,000 $0 $0 $0 $0 $14,000
Current Penalty $14,000 $0 $0 $0 $0 $14,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100134 A02 01/09/2009 02/27/2009 $3,500 $3,500 $0 -  
2. 01001B Serious 19100134 K03 01/09/2009 02/27/2009 $0 $0 $0 -  
3. 01001C Serious 19100134 D01 I 01/09/2009 02/27/2009 $0 $0 $0 -  
4. 01001D Serious 19100134 D01 III 01/09/2009 02/27/2009 $0 $0 $0 -  
5. 01002 Serious 19101200 H01 01/09/2009 02/05/2009 $3,500 $3,500 $0 -  
6. 01003 Serious 19260021 B06 I 01/09/2009 02/05/2009 $3,500 $3,500 $0 -  
7. 01004A Serious 19260055 A 01/09/2009 01/14/2009 $3,500 $3,500 $0 -  
8. 01004B Serious 19260055 B 01/09/2009 01/14/2009 $0 $0 $0 -  
9. 02001 Other 19100134 E01 01/09/2009 02/27/2009 $0 $0 $0 -  
10. 02002 Other 19100134 F02 01/09/2009 02/27/2009 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200357176
Event: 08/25/2008
Two Employees Suffer from Carbon Monoxide Exposure

At approximately 1:30 p.m. on August 25, 2008, Employee #1 began using a portable gas powered concrete saw at the bottom of 22-ft deep by 8-ft wide sanitary sewer manhole structure. Employee #2 was assisting Employee #1 by providing fuel and holding a fan adjacent to Employee #1. The fan was lowered into the hole through the use of a rope. The fan was not connected to a fresh air supply. Employees were wearing inappropriate respiratory protection. At 1:45 p.m., Employee #1 began to show signs of carbon monoxide, CO, overexposure. As Employee #2 began to assist Employee #1, he too began to show signs of CO overexposure. Employee #2 cried to the foreman at the surface to call for emergency services. The foreman called emergency medical services at approximately 2:00 p.m. At 2:09 p.m., the fire department arrived and began to ventilate the manhole. The employees were removed from the space and sent for medical treatment. The employees were not hospitalized.

Keywords: ASPHYXIATED, FAN, CONFINED SPACE, PPE, CONSTRUCTION, SAW, MANHOLE, CARBON MONOXIDE, RESPIRATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312447303 Non Hospitalized injury Asphyxia Construction laborers
2 312447303 Non Hospitalized injury Asphyxia Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.