Powered by GoogleTranslate

Inspection Detail

Inspection: 309339356 - International Specialty Alloys, Inc.

Inspection Information - Office: Erie Area Office

 

Inspection Nr: 309339356
Report ID: 0336000
Date Opened: 08/29/2007

Site Address:
International Specialty Alloys, Inc.
599 Northgate Circle
New Castle, PA 16105

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3339

NAICS: 331419/Primary Smelting and Refining of Nonferrous Metal (except Copper and Aluminum)


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/13/2007

Emphasis: S:Amputations, S:Electrical, S:Powered Ind Vehicle, S:Struck-By

Case Closed: 08/11/2008


Related Activity
Type Activity Nr Safety Health
Referral 200386092 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 2 2
Initial Penalty $9,206 $0 $0 $0 $0 $9,206
Current Penalty $5,500 $0 $0 $0 $0 $5,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 02/26/2008 08/08/2008 $4,500 $4,500 $0 R - Review Commission  
2. 01002 Serious 19100022 A01 02/26/2008 02/29/2008 $0 $956 $0 R - Review Commission Citation has been deleted.
3. 01003A Serious 19100023 C01 02/26/2008 03/17/2008 $1,000 $1,875 $0 R - Review Commission  
4. 01003B Other 19100023 E03 IV 02/26/2008 03/17/2008 $0 $0 $0 R - Review Commission  
5. 01004A Serious 19100132 D01 02/26/2008 04/01/2008 $0 $1,875 $0 R - Review Commission Citation has been deleted.
6. 01004B Serious 19100133 A01 02/26/2008 03/17/2008 $0 $0 $0 R - Review Commission Citation has been deleted.

Investigation Summary

Investigation Nr: 200380780
Event: 08/29/2007
Three Employees Are Injured in Explosion

At approximately 9:30 a.m. on August 29, 2007, Employee #1, #2, and #3 were injured when an explosion from the combustible metal thermite reaction operation blew apart a bunker complex. The entire building sustained damage from a deflagration type explosion including a large hole in the roof, blow outs to the perimeter walls, and deforming interior structural members. All three sustained injuries from the pressure and or heat wave. Employee #1 was hospitalized with burns to his head. Employee's #2 and #3 were treated and released for concussions.

Keywords: BURN, HEAD, EXPLOSION, CHEMICAL REACTION, STRUCK BY, CONCUSSION, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309339356 Hospitalized injury Burn/Scald(Heat) Laborers, except construction
2 309339356 Non Hospitalized injury Concussion Laborers, except construction
3 309339356 Non Hospitalized injury Concussion Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.