Powered by GoogleTranslate

Inspection Detail

Inspection: 305223174 - Juan Oliveros & Son

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 305223174
Report ID: 0420600
Date Opened: 03/10/2002

Site Address:
Juan Oliveros & Son
Parnell Rd.
Zolfo Springs, FL 33890

Mailing Address:
837 Lake Chiles Rd P.O.Box 2415, Lake Placid, FL 33862

Union Status: NonUnion

SIC:0722

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/28/2002

Emphasis: L:Ohpwrlne, S:Food Processing

Case Closed: 01/17/2003


Related Activity
Type Activity Nr Safety Health
Accident 102340296
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 08/05/2002 08/08/2002 $0 $0 $0 08/21/2002 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 202327607
Event: 03/09/2002
Farm Worker Is Elecrocuted When Vehicle Contacts Power Line

On March 9, 2002, Employee #1 and Employee #2 were harvesting fruit, using two pieces of equipment, called "Goats," to unload boxes for the fruit. Employee #1 was operating one of the Goats in a drive row unloading boxes while Employee #2 was in another row unloading boxes. There were approximately four rows of trees between the two rows on which the Goats were being operated. While Employee #1 was unloading a box, he had the boom extended in the air, and he snagged the neutral conductor of an overhead power line. When Employee #1 was lowering the boom, the neutral line was still snagged and lowering the boom strained the neutral, causing a previously broken pole to fall. This considerably lowered the height of the neutral as well as a phase wire of the overhead power line. Employee #1 noticed the Goat's tires burning and so shut off the Goat and stepped off. The phase wire was in contact with the Goat and had caused the tires to burn. When the feet of Employee #1 touched the ground, he was still holding onto the Goat, which made him a path to ground. Employee #1 was killed by electric shock from the electrical contact.

Keywords: E GI III, BOOM, AGRICULTURE, ELECTROCUTED, GROUND FAULT, ELECTRIC SHOCK, FRUIT PACKING, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305223174 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close