Inspection: 303578678 - Bp, Cooper River Division

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 303578678
Report ID: 0454510
Date Opened: 03/26/2001

Site Address:
Bp, Cooper River Division
1306 Amoco Drive
Wando, SC 29492

Mailing Address:
150 West Warrenville Rd Mail Code P-1, Naperville, IL 60563

Union Status: NonUnion

SIC:2819

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/01/2001

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 07/06/2001


Related Activity
Type Activity Nr Safety Health
Accident 100372135
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $5,625 $0 $0 $0 $0 $5,625
Current Penalty $5,625 $0 $0 $0 $0 $5,625
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 10012 A 05/15/2001 06/18/2001 $1,875 $1,875 $0 -  
2. 01002 Serious 10012 A 05/15/2001 06/18/2001 $1,875 $1,875 $0 -  
3. 01003 Serious 19100132 D01 05/15/2001 06/18/2001 $1,875 $1,875 $0 A - Amendment  

Investigation Summary

Investigation Nr: 170571921
Event: 03/26/2001
Two Employees Had Burns And One Had Fractured His Head

At approximately 10:00 a.m. on March 26, 2001, three contractors, Employee #1-#3, were assigned the job duty of removing a blind flange cover during a chemical plant shut down. Employees #1 and #2 were removing the cover with a pneumatic air tool (impact wrench) while Employee #3 stacked bolts and assisted with the tools. Employees #1 and #2 were on top of the reactor removing the cover and Employee #3 was about eight to ten feet away. The friction or static from the cover removal ignited an explosive atmosphere of hydrogen and air in the reactor. Employee #1 and #3 were burned around the head and neck. Employee #2 was struck in the head by the 275 pound cover. All three employees went to a local hospital for treatment.

Keywords: BURN, FRACTURE, HEAD, IGNITION SYSTEM, NECK, STRUCK BY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303578678 Hospitalized injury Burn/Scald(Heat) Supervisors, mechanics and repairers
2 303578678 Hospitalized injury Fracture Plumber, pipefitter and steamfiter apprentices
3 303578678 Hospitalized injury Burn/Scald(Heat) Plumber, pipefitter and steamfiter apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.