Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1458010.015 - Hydro Extrusion Usa, Llc

Inspection Information - Office: Sioux Falls Area Office

 

Inspection Nr: 1458010.015
Report ID: 0830400
Date Opened: 01/23/2020

Site Address:
Hydro Extrusion Usa, Llc
2500 Alumax Road
Yankton, SD 57078

Mailing Address:
2500 Alumax Road, Yankton, SD 57078

Union Status: NonUnion

SIC:

NAICS: 423510/Metal Service Centers and Other Metal Merchant Wholesalers


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/23/2020

Emphasis: P:Amputate, N:Amputate

Case Closed: 07/15/2020


Related Activity
Type Activity Nr Safety Health
Referral 1537391 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1
Initial Penalty $9,543 $0 $0 $0 $0 $9,543
Current Penalty $6,000 $0 $0 $0 $0 $6,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100212 A01 06/18/2020 07/15/2020 $6,000 $9,543 $0 I - Informal Settlement  
2. 01001B Serious 19100212 A03 II 06/18/2020 07/15/2020 $0 $0 $0 I - Informal Settlement  
3. 02001 Other 19100303 G01 06/18/2020 $0 $0 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 123403.015
Event: 01/22/2020
Employee amputates finger in material stretcher machine

At 4:00 a.m. on January 22, 2020, an employee was operating the tail end of a aluminum profile material stretcher, actuating the stretcher foot to remove the material however, the material remained fastened to the stretcher foot when it was actuated to the unfasten position. The employee put his left index finger on the material to unfasten it when the material broke free of the foot and crushed his finger between the material and the machine. The employee was hospitalized to treat an amputation of tip of his left index finger.

Keywords: Aluminum Processing, Amputated, Amputation, Caught Between, Clearing, Crushed, Finger, Fingertip, Jammed, Machine operator, Partial Amputation, Unloading

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1458010.015 39 M Hospitalized injury Extruding and forming machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.