Inspection Detail
Inspection: 1453651.015 - Select Industries Corporation
Inspection Information - Office: Cincinnati Area Office
Site Address:
Select Industries Corporation
60 Heid Drive
Dayton, OH 45401
Mailing Address:
60 Heid Drive, Dayton, OH 45401
Union Status: NonUnion
SIC:
NAICS: 336370/Motor Vehicle Metal Stamping
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/12/2020
Emphasis: L:Piv
Case Closed: 02/23/2021
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1530704 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $34,699 | $0 | $0 | $0 | $0 | $34,699 |
| Current Penalty | $9,021 | $0 | $0 | $0 | $0 | $9,021 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100147 C06 I | 02/13/2020 | 03/04/2020 | $4,511 | $10,409 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100303 G02 II | 02/13/2020 | 03/11/2020 | $0 | $12,145 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 3. | 01003A | Serious | 19100333 A | 02/13/2020 | 03/11/2020 | $4,511 | $12,145 | $0 | I - Informal Settlement | ||
| 4. | 01003B | Serious | 19100333 C02 | 02/13/2020 | 03/11/2020 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At 5:00 p.m. on December 30, 2019, an employee was resetting the Variable Frequency Drive on a straightener for a mechanical press. After the employee reset the button, he noted the cover on the circuit board was not sitting right. The employee grabbed the cover to adjust it. The employee's finger was able to touch the circuit board due to a broken tab. The employee was shocked by the 340 volts circuit panel. The employee sustained unspecified injuries and was hospitalized for treatment.
Keywords: Circuit Breaker, Electric Shock, Finger, Mechanical Power Press, Shock
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1453651.015 | 34 | M | Hospitalized injury |