Inspection Detail
Inspection: 1313153.015 - Pci Procoaters, Inc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
Pci Procoaters, Inc.
5259 Minola Drive
Lithonia, GA 30038
Mailing Address:
5259 Minola Drive, Lithonia, GA 30038
Union Status: NonUnion
SIC:
NAICS: 332322/Sheet Metal Work Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/08/2018
Emphasis:
Case Closed: 06/11/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1331963 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $8,410 | $0 | $0 | $0 | $0 | $8,410 |
| Current Penalty | $5,046 | $0 | $0 | $0 | $0 | $5,046 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100252 A02 IV | 05/30/2018 | $2,523 | $4,205 | $0 | I - Informal Settlement | |||
| 2. | 01002 | Serious | 19100252 A02 VI C | 05/30/2018 | $2,523 | $4,205 | $0 | I - Informal Settlement |
Investigation Summary
At 6:15 a.m. on April 26, 2018, an employee was cutting the top off four 55 gallon drums that used to contained MEK or 2-Butanone. The employee cut the top off of three drums and placed his torch on top of the fourth drum prior to cutting it and the drum exploded. The employee was struck by the top and was hospitalized with multiple facial fractures and head trauma.
Keywords: Chemical Vapor, Drum, Explosion, Face, Fire, Flammable Vapors, Flying Object, Fracture, Head, Struck By, Torch
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1313153.015 | 55 | M | Hospitalized injury |
Translate