Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1215387.015 - Crown Plastics

Inspection Information - Office: Saint Louis Area Office

 

Inspection Nr: 1215387.015
Report ID: 0729300
Date Opened: 03/07/2017

Site Address:
Crown Plastics
918 Airport Road
Festus, MO 63028

Mailing Address:
918 Airport Road, Festus, MO 63028

Union Status: NonUnion

SIC:

NAICS: 326199/All Other Plastics Product Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/15/2017

Emphasis: N:Amputate

Case Closed: 04/06/2017


Related Activity
Type Activity Nr Safety Health
Referral 1187486 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $23,133 $0 $0 $0 $0 $23,133
Current Penalty $11,567 $0 $0 $0 $0 $11,567
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100147 C04 II 03/17/2017 04/12/2017 $2,694 $5,387 $0 I - Informal Settlement  
2. 01001B Serious 19100147 C05 I 03/17/2017 $0 $0 $0 I - Informal Settlement  
3. 01002 Serious 19100147 C07 I B 03/17/2017 04/12/2017 $4,437 $8,873 $0 I - Informal Settlement  
4. 01003 Serious 19100147 D03 03/17/2017 04/12/2017 $4,437 $8,873 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 93706.015
Event: 03/01/2017
Worker reaches into machine and finger is amputated

At 5:30 a.m. on March 1, 2017, Employee #1, employed by a plastics manufacturer, was operating the Global Mattic machine. Employee #1 reported that he heard a noise and thought it might be a loose belt. Employee #1 thought he was pushing the machine's off button but pushed the reverse button instead. He opened the guard door and reached in, thinking the machine was turned off. His hand came into contact with the drive belt, the belt reversed its motion, and Employee #1's fingers became caught in the belt. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for the amputation of his right little finger and lacerations to his right ring and middle fingers.

Keywords: Amputation, Belt, Caught In, Control Lever, Finger, Hand, Laceration, Machine Guarding, Maintenance, Unsecured

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1215387.015 58 M Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.