Inspection Detail
Inspection: 108752346 - J & L Specialty Steel
Inspection Information - Office: Pittsburgh Area Office
Site Address:
J & L Specialty Steel
12th & Midland Avenue
Midland, PA 15059
Mailing Address:
, , 00000
Union Status: Union
SIC:3312
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 08/26/1993
Emphasis:
Case Closed: 01/06/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 900887183 | Yes | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $4,500 | $0 | $0 | $0 | $0 | $4,500 |
| Current Penalty | $2,900 | $0 | $0 | $0 | $0 | $2,900 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 09/03/1993 | 01/05/1994 | $2,900 | $4,500 | $0 | I - Informal Settlement |
Investigation Summary
During the completion of a heat on an argon oxygen defuser vessel, molten metal burned through the refractory brick, the safety lining, and the metal housing of the vessel into a water-cooled trunion ring. A series of explosions ensued. Employees #1 and #2 were hospitalized with burns on their hands.
Keywords: BURN, EQUIPMENT FAILURE, EXPLOSION, MOLTEN METAL, HAND, HIGH TEMPERATURE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 108752346 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 108752346 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |