Powered by GoogleTranslate

Inspection Detail

Inspection: 103044293 - Bt Energy, Inc.

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 103044293
Report ID: 0522500
Date Opened: 12/23/1991

Site Address:
Bt Energy, Inc.
Washington County Road 60
Lowell, OH 45744

Mailing Address:
450 S. State Street, New Lexington, OH 43764

Union Status: NonUnion

SIC:1389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Health

Close Conference: 12/23/1991

Emphasis:

Case Closed: 03/19/1993


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 9 9
Current Violations 8 8
Initial Penalty $8,550 $0 $0 $0 $0 $8,550
Current Penalty $4,290 $0 $0 $0 $0 $4,290
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 06/19/1992 07/22/1992 $825 $1,500 $0 I - Informal Settlement  
2. 01002 Serious 19100023 C01 06/19/1992 07/22/1992 $330 $600 $0 I - Informal Settlement  
3. 01003 Serious 19100027 D03 06/19/1992 07/22/1992 $330 $600 $0 I - Informal Settlement  
4. 01004 Serious 19100120 Q01 06/19/1992 07/22/1992 $825 $1,500 $0 I - Informal Settlement  
5. 01005 Serious 19100132 A 06/19/1992 07/22/1992 $825 $1,500 $0 I - Informal Settlement  
6. 01006 Serious 19100219 F03 06/19/1992 07/07/1992 $330 $600 $0 I - Informal Settlement  
7. 01007 Serious 19101200 E01 06/19/1992 07/22/1992 $413 $750 $0 I - Informal Settlement  
8. 01008 Serious 19101200 G01 06/19/1992 07/22/1992 $750 $750 $0 I - Informal Settlement Citation has been deleted.
9. 01009 Serious 19101200 H01 06/19/1992 07/22/1992 $412 $750 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14524821
Event: 12/20/1991
Employees injured during oil/gas well explosion

During plugging and abandoning operations at an oil/gas well, a kick or blowout occurred while a service company was pumping a cement plug into the hole. No blowout prevention devices were used, and flammable concentrations of gas accumulated around the well. A diesel pickup truck that was left running 40 feet away from the well began to overspeed, or diesel, as a result of the natural gas entering the air intake. The truck did not have a kill switch or a heat and spark arresting exhaust system, and it subsequently ignited the surrounding vapors, causing an explosion. Employees #1 through #5 were injured.

Keywords: FLAMMABLE VAPORS, WORK RULES, EXPLOSION, BLOWOUT--OIL WELL, PICKUP TRUCK, NATURAL GAS, OIL WELL SERVICING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103044293 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 103044293 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 103044293 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.