Powered by GoogleTranslate

Inspection Detail

Inspection: 100816792 - National Tank Company - Wichita Falls Site

Inspection Information - Office: Fort Worth Area Office

 

Inspection Nr: 100816792
Report ID: 0636900
Date Opened: 08/27/1990

Site Address:
National Tank Company - Wichita Falls Site
8505 Jacksboro Highway
Wichita Falls, TX 76307

Mailing Address:
P. O. Box 5123, Wichita Falls, TX 76307

Union Status: NonUnion

SIC:3443

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/29/1990

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 08/26/1992


Related Activity
Type Activity Nr Safety Health
Accident 360344659
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 2
Initial Penalty $1,800 $9,000 $0 $0 $0 $10,800
Current Penalty $0 $0 $0 $900 $0 $900
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19101200 H 02/20/1991 03/11/1991 $0 $900 $0 03/15/1991 J - ALJ Decision  
2. 01002 Other 19100253 D04 II 02/20/1991 03/11/1991 $900 $900 $0 03/15/1991 J - ALJ Decision  
3. 02001 Willful 5A0001 02/20/1991 02/23/1991 $9,000 $9,000 $0 03/15/1991 J - ALJ Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 565804
Event: 08/24/1990
One employee killed and two injured in explosion

Employees #2 and #3, outside contractor personnel, were observing and testing recently deposited welds inside an 8 ft diameter by 24 ft long steel pressure vessel. Employee #1 was entering the vessel through a 20 in. diameter manway to grind a weld at the request of one of the two outside contractor personnel. An explosion occurred within the vessel and the force of the explosion propelled Employee #1 approximately 27 ft into a stationary steel cabinet, causing severe injuries that resulted in his death. Employees #2 and #3 were severely burned and were hospitalized. The introduction of lpg (possibly propane) into the tank from an unmarked piping system and hose, and at the same time, the activation of an ignition source (possibly an electric drop-light or the flash from a cigarette lighter) caused the explosion. The vessel manufacturer had a thorough confined space entry/work procedure that had not been implemented at this plant.

Keywords: BURN, CONFINED SPACE, PPE, PRESSURE VESSEL, WORK RULES, FIRE, EXPLOSION, LP GAS, PROPANE, SPARK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100816792 Fatality Burn/Scald(Heat) Occupation not reported
2 100816792 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 100816792 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.