Inspection: 100026525 - Veco Drilling, Inc.

Inspection Information - Office: Denver Area Office

 

Inspection Nr: 100026525
Report ID: 0830500
Date Opened: 08/07/1991

Site Address:
Veco Drilling, Inc.
East Of Wcr Rd. 29, & Hwy 85
Gilcrest, CO 80623

Mailing Address:
785 22 Rd., Grand Junction, CO 81502

Union Status: NonUnion

SIC:1381

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/17/1992

Emphasis:

Case Closed: 03/06/1992


Related Activity
Type Activity Nr Safety Health
Accident 360367650
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $2,250 $0 $0 $0 $0 $2,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 5A0001 01/28/1992 02/28/1992 $2,250 $4,500 $0 I - Informal Settlement  
2. 01001B Serious 5A0001 01/28/1992 02/28/1992 $0 $0 $0 -  
3. 02001 Other 19101200 E01 01/28/1992 02/28/1992 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 930651
Event: 08/06/1991
Four employees burned by natural gas flash fire

Employees #1 through #5 were members of a rig crew that had just come out of the hole to add a section of pipe when they experienced a kick. Natural gas began spewing from the well and up through the rig floor. When they attempted to close in the well using the provided Hydril blowout prevention, the unit failed to close fully and gas continued to accumulate in the area and eventually ignited. The resulting flash fire caused serious burns to Employees #1, #2, #3, and #5. The employees had not had blowout protection classes and had not been trained in appropriate inspection, maintenance, and testing procedures for the Hydril. The Hydril was not tested either upon installation on the well or upon the occurrence of a round trip the previous day.

Keywords: EQUIPMENT FAILURE, INEXPERIENCE, BLOWOUT--OIL WELL, GAS WELL DRILLING, UNTRAINED, BURN, FLAMMABLE LIQUID, FIRE, NATURAL GAS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100026525 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 100026525 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 100026525 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 100026525 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
5 100026525 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.