Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200357176 - Two Employees Suffer from Carbon Monoxide Exposure

Accident Summary Nr: 200357176 -- Report ID: 0453710 -- Event Date: 08/25/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31244730308/26/20081623237110Harrelson Utilities, Inc.

Abstract: At approximately 1:30 p.m. on August 25, 2008, Employee #1 began using a portable gas powered concrete saw at the bottom of 22-ft deep by 8-ft wide sanitary sewer manhole structure. Employee #2 was assisting Employee #1 by providing fuel and holding a fan adjacent to Employee #1. The fan was lowered into the hole through the use of a rope. The fan was not connected to a fresh air supply. Employees were wearing inappropriate respiratory protection. At 1:45 p.m., Employee #1 began to show signs of carbon monoxide, CO, overexposure. As Employee #2 began to assist Employee #1, he too began to show signs of CO overexposure. Employee #2 cried to the foreman at the surface to call for emergency services. The foreman called emergency medical services at approximately 2:00 p.m. At 2:09 p.m., the fire department arrived and began to ventilate the manhole. The employees were removed from the space and sent for medical treatment. The employees were not hospitalized.

Keywords: ASPHYXIATED, FAN, CONFINED SPACE, PPE, CONSTRUCTION, SAW, MANHOLE, CARBON MONOXIDE, RESPIRATOR
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition $50,000 to $250,000 22

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 312447303 Non Hospitalized injury Asphyxia Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Asphyxiation/inhalation of toxic vapor
2 312447303 Non Hospitalized injury Asphyxia Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Asphyxiation/inhalation of toxic vapor

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close