Letters of Interpretation

OSHA requirements are set by statute, standards, and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. Each letter constitutes OSHA's interpretation of the requirements discussed.

Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information.

These letters of interpretation and the standards they address may not apply to OSHA State Plans. State Plans are required to have standards and enforcement programs that are at least as effective as OSHA's and may have different or additional requirements. Please see OSHA-approved State Plans for more information.

Filters


Date Title Standard Number
Apparel requirements for line-clearence tree-trimmers 1910.269
Successor liability for employee exposure and medical records. 1910.1020(c)(7), 1910.1020(h)
Worker exposure to tobacco smoke. 1910.1000
Application of 1910.147 to the change out of a grinding wheel. 1910.147(a)(2)(ii), 1910.147(a)(2)(iii)(A)
Validity of Illustrations in the Confined Space Standard Appendices. 1910.146 App C, 1910.146 App D, 1910.146 App E
Conduct of respiratory protection medical evaluations by medical technicians. 1910.134, 1910.134(e)(2)(i)
Health care professional's discretion regarding medical evaluations and exams. 1910.134(e)
Questions and answers regarding the respiratory protection standard 1910.134
Difference between "grain elevators" and "grain handling facilities" 1910.272(j)
Respiratory protection for work on dichlorobenzidine (DCP) contaminated equipment. 1910.1003(c)(5)(i)
Using the telephone to back-up eletronic access to MSDSs. 1910.1200(g)(8)
Definition of a mixture under the Hazard Communication standard. 1910.1200(c)
"Representative sampling" provisions of the Methylene Chloride standard. 1910.1052(d)(1)(ii)
Respiratory Protection Standard: Interim Enforcement Policy. 1910.134, 1926.103
Requirements for machine guarding of screw machines. 1910.212(a)
Medical evaluation requirements under the respiratory protection standard 1910.134(c), 1910.134(e)
Bloodborne Pathogens standard: Group purchasing agreements in healthcare facilities; engineering controls. 1910.1030
Applicable standards for Below-the-Hook Lifting Devices and slings. 1910.184
Powered platforms: Suspension height limits for transportable outriggers. 1910.66(f)(3)(ii), 1910.66(e)(2)
All exterior openings/doors of temporary labor housing must be screened. 1910.142(b)(8)