US Dept of Labor

Occupational Safety & Health AdministrationWe Can Help

Alphabetic Index of Sampling and Analytical Methods - T

Substance and Method Number CAS Number(s) Instrument / Sampler
Tellurium; ID121; Fully Validated 13494-80-9 AA; MCEF
Tellurium; ID132SG; Partially Validated 7783-80-4 AA/HGA; MCEF
Temephos; PV2056; Partially Validated 3383-96-8 HPLC/UV; GFF
Temik; 74; Fully Validated 116-06-3 GC/NPD; OVS-2
Testosterone; PV2001; Partially Validated 58-22-0 HPLC/UV; GFF
1,1,1,2-Tetrachloro-1,2-difluoroethane; 7 76-11-9 GC/FID; CSC
1,1,2,2-Tetrachloro-1,2-difluoroethane; 7 79-34-5 GC/FID; CSC
Tetrachloroethylene; 1001; Fully Validated 127-18-4
  • GC/FID; CSC or
  • SKC 575-002
2,3,4,6-Tetrachlorophenol; 45; Fully Validated 25167-83-3 HPLC/UV; XAD-7
Tetrahydrofurfuryl Acrylate; PV2131; Partially Validated 2399-48-6 GC/FID; Chromosorb 106
Tetraethyltin; 110; Fully Validated 597-64-8 GC/FID; XAD-7
Tetrahydrofuran; 7 109-99-9 GC/FID; CSC
Tetramethyl Succinonitrile; 7 3333-52-6 GC/FID; CSC
Tetramethyltin; PV2057; Partially Validated 23564-06-9 GC/FID; CSC
Thallium; ID121; Fully Validated 7440-28-0 AA; MCEF
Thiophanate-Methyl; PV2058; Partially Validated 23564-06-8 HPLC/UV; GFF
Thiourea; PV2059; Partially Validated 62-56-6 HPLC/UV; GFF
l -Thyroxine; PV2117; Partially Validated 51-48-9 HPLC/UV; GFF
Tin; ID121; Fully Validated 7440-31-5 AA; MCEF
Tin; ID206; Fully Validated 7440-31-5 ICP; MCEF
Titanium; ID121; Fully Validated 7440-32-6 AA; MCEF
o-Tolidine; 71; Fully Validated 119-93-7 GC/ECD; GFF coated with Sulfuric Acid
Toluene; 111; Fully Validated 108-88-3 GC/FID; CSC, Anasorb 747, SKC 575-002, or 3M 3520
2,4-Toluenediamine; 65; Fully Validated 95-80-7 GC/ECD; GFF coated with Sulfuric Acid
2,6-Toluenediamine; 65; Fully Validated 823-40-5 GC/ECD; GFF coated with Sulfuric Acid
Toluene-2,4-diisocyanate - (TDI); 18; Fully Validated 584-84-9 HPLC/UV; Bubbler with Nitro Reagent
Toluene-2,4-diisocyanate; 33; Fully Validated 584-84-9 HPLC/TEA; Bubbler with Nitro Reagent
Toluene-2,4-diisocyanate - (TDI); 42; Fully Validated 584-84-9 HPLC/FL; GFF coated with 12PP
Toluene-2,6-diisocyanate; 42; Fully Validated 91-08-7 HPLC/FL; GFF coated with 12PP
m-Toluidine; 73; Fully Validated 108-44-1 GC/ECD; GFF coated with Sulfuric Acid
o-Toluidine; 73; Fully Validated 95-53-4 GC/ECD; GFF coated with Sulfuric Acid
p-Toluidine; 73; Fully Validated 106-49-0 GC/ECD; GFF coated with Sulfuric Acid
Tributyltin Benzoate; ID222SG; Partially Validated 7440-31-5 AA/HGA; PVC
Tributyltin Fluoride; ID223SG; Partially Validated 7440-31-5 AA; PVC
Trichloroacetic Acid; PV2017; Partially Validated 76-03-9 HPLC/UV; Silica Gel
1,1,1-Trichloroethane; 14; Fully Validated 71-55-6 GC/FID; CSC
1,1,2-Trichloroethane; 11; Fully Validated 79-00-5 GC/FID; CSC
Trichloroethylene; 1001; Fully Validated 79-01-6
  • GC/FID; CSC or
  • SKC 575-002
Trichloroisocyanuric Acid; ID101SG; Partially Validated 87-90-1 ISE; PTFE Filter followed with bubbler containing Sulfamic Acid
1,2,3-Trichloropropane; 7 96-18-4 GC/FID; CSC
1,1,2-Trichloro-1,2,2-Trifluoroethane; 113; Fully Validated 76-13-1 GC/FID; Anasorb CMS
Triethanolamine; PV2141; Partially Validated 102-71-6 GC/FID; GFF
Triethylamine; PV2060; Partially Validated 121-44-8 GC/FID; XAD-7 coated with Phosphoric Acid
Triethylenetetramine; 60; Fully Validated 112-24-3 HPLC/UV; XAD-2 coated with NITC
1,3,5-Triglycidyl Isocyanurate; PV2055; Partially Validated 2451-62-9 GC/ECD; GFF coated with Hydrogen Bromide
Trimellitic Anhydride; 98; Fully Validated 552-30-7 HPLC/UV; GFF coated with Veratriamine and DOP
Trimethylamine; PV2060; Partially Validated 75-50-3 GC/FID; XAD-7 coated with Phosphoric Acid
Trimethylbenzenes; PV2091; Partially Validated
  • 526-73-8
  • 96-63-6
  • 108-67-8
2,2,4-Trimethyl-1,3-Pentanediol Diisobutyrate; PV2002; Partially Validated 6846-50-0 GC/FID; Chromosorb 106
2,4,6-Trinitrotoluene; 44; Fully Validated 118-96-7 HPLC/TEA; GFF followed by Tenax
Triphenyltin Hydroxide; ID225SG; Partially Validated 7440-31-5 AA/HGA; MCEF
Tripoli; ID142; Fully Validated 1317-95-9 X-Ray Diffraction; Low Ash PVC with Cyclone
Tungsten; ID213; Fully Validated 7440-48-4 ICP; MCEF

Search Sampling and Analytical Methods

collage image - OSHA Salt Lake Technical Center
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.