Lapse in Appropriations
For workplace safety and health, please call 800-321-6742; for mine safety and health, please call 800-746-1553; for Job Corps, please call 800-733-5627 and for Wage and Hour, please call 866-487-9243 (866-4-US-WAGE). This website is currently not being updated due to the suspension of Federal government services. The last update to the site was 10/1/2025. Updates to the site will start again when the Federal government resumes operations.
METHYLENE CHLORIDE (DICHLOROMETHANE)‡
| CAS # | 75-09-2 | 
|---|---|
| Formula | CH₂Cl₂ | 
| Synonyms | dichloromethane; methylene dichloride | 
| Physical description | Colorless liquid with a chloroform-like odor. | ||
|---|---|---|---|
| Boiling point | 104°F | Molecular weight | 84.9 | 
| Freezing point/melting point | -139°F | Vapor pressure | 350 mmHg | 
| Flash point | Vapor density | 2.93 | |
| Specific gravity | 1.33 | Ionization potential | 11.32 eV | 
| Lower explosive limit (LEL) | 13% | Upper explosive limit (UEL) | 23% | 
| NFPA health rating | 2 | NFPA fire rating | 1 | 
| NFPA reactivity rating | 0 | NFPA special instruction | |
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 1730 | 
|---|---|
| Sampling group | |
| Sampler/Sampling media | 2 Anasorb 747 sampling tubes (6 mm glass tubes, the front tube contains 400 and the back 200 mg of sorbent) connected in series [SKC 226-82], tube holder [SKC 222-3L-1], Type D cover [SKC 224-29D] | 
| Sampling time* | 240 min TWA; 15 min STEL | 
| Sampling volume (TWA)* | 12 L | 
| Sampling flow rate (TWA)* | 0.05 L/min | 
| Sampling volume (STEL/Peak/C)* | 0.75 L | 
| Sampling flow rate (STEL/Peak/C)* | 0.05 L/min | 
| Analytical method instruments | GC-FID | 
| Method reference | OSHA 1025 (fully validated) | 
| Notes | |
| Special requirements | 
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media | |
|---|---|
| Bulk Method | 
| Device | CMS Chip | 
|---|---|
| Model/Type | Methylene chloride, 10-200 ppm range | 
| Sampling information (see manufacturer instructions) | 
| 
                                  OSHA PEL 8-hour TWA (ST) STEL (C) Ceiling Peak | 
                                  NIOSH REL Up to 10-hour TWA (ST) STEL (C) Ceiling | 
                                  ACGIH TLV© 8-hour TWA (ST) STEL (C) Ceiling | |||||
|---|---|---|---|---|---|---|---|
| PEL-TWA | 25 ppm [12.5 ppm Action Level] | REL-TWA | TLV-TWA | 50 ppm [1997] | PEL-TWA | 25 ppm (87 mg/m³) | |
| PEL-STEL | 125 ppm | REL-STEL | TLV-STEL | PEL-STEL | 125 ppm (435 mg/m³) | ||
| PEL-C | REL-C | TLV-C | PEL-C | ||||
| Skin notation | Y | Skin notation | Y | Skin notation | N | Skin notation | N | 
| Notes: See 29 CFR 1910.1052 | Notes: CARCINOGEN (Ca): REDUCE EXPOSURE TO LOWEST FEASIBLE CONCENTRATION. See Appendix A, NIOSH Potential Occupational Carcinogens. | Notes: BEI® | Notes: See also Section 5202. | ||||
| Health factors: See NIH-NLM PubChem. | IDLH | 2300 ppm | |||||
| Carcinogenic classifications: IARC-2B, NIOSH-Ca, EPA-B2, NTP-R, OSHA-Ca, TLV-A3 | Notes: Ca | ||||||
| AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3: 300 ppm/750 ppm/4000 ppm | |||||||
Additional Resources and Literature References
| NOAA: CAMEO Chemicals - Dicholoromethane NIOSH: Pocket Guide to Chemical Hazards - Methylene chloride Literature References 
 | 
Last Updated Date : 01/06/2024