Hoisting personnel.

  • Part Number:
  • Part Number Title:
  • Title:
  • GPO Source:

The requirements of this section are supplemental to the other requirements in this subpart and apply when one or more employees are hoisted.

Hoisting Employees in boatswain’s chair to perform boat-building and boat-repair work

Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

OSHA requirements are set by statute, standards and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of the requirements discussed. Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information. To keep apprised of such developments, you can consult OSHA's website at https://www.osha.gov.

March 12, 2013

Susan Swanton
Executive Director
Maine Marine Trades Association
P.O. Box 3551
Portland, ME 04104

Dear Ms. Swanton:

Clarification of requirements for construction scaffold erection/dismantling; safe means of access; blocks for two-point suspension scaffolds.

OSHA requirements are set by statute, standards and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of the requirements discussed. Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information. To keep apprised of such developments, you can consult OSHA's website at https://www.osha.gov.

January 2, 2002

Ms. Carmen Shafer
Assistant Director of Safety and Health
The Associated General Contractors of America
AGC B Indiana
1050 Market Tower
10 West Market Street
Indianapolis, IN 46204

Re: 1926.451(a)(3), (a)(4), (b)(1)(i), (c)(1)(iii), (d)(16), (d)(17), (f)(3), (e), (e)(9)(i), (e)(9)(ii), (e)(9)(iii), (e)(9)(iv), (g)(1), (g)(4)(i), 1926.452(p)(3), 1926.1431

Dear Ms. Shafer:

Kiewit Power Constructors Co. et al.; Application for a Permanent Variance and Request for Comments

  • Publication Date:
  • Publication Type:
  • Fed Register #:
    78:17432-17448
  • Title:
[Federal Register Volume 78, Number 55 (Thursday, March 21, 2013)][Notices][Pages 17432-17448]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 2013-06509]


=======================================================================
-----------------------------------------------------------------------

DEPARTMENT OF LABOR

Occupational Safety and Health Administration

[Docket No. OSHA-2012-0015]


Kiewit Power Constructors Co.

Kiewit Power Constructors Co. et al. [Avalotis Corp., Bowen Engineering Corporation, Commonwealth Dynamics, Inc., Gibraltar Chimney International, LLC, Hamon Custodis, Inc., Hoffmann, Inc., International Chimney Corporation, Karrena International Chimney,

  • Publication Date:
  • Publication Type:
  • Fed Register #:
    78:60900-60918
  • Title:
    [Federal Register Volume 78, Number 191 (Wednesday, October 2, 2013)]
    [Notices]
    [Pages 60900-60918]
    From the Federal Register Online via the Government Printing Office [www.gpo.gov]
    [FR Doc No: 2013-23625]
    
    
    -----------------------------------------------------------------------
    
    DEPARTMENT OF LABOR
    
    Occupational Safety and Health Administration
    
    [Docket No. OSHA-2012-0015]
    
    
    Kiewit Power Constructors Co. et al.