Powered by GoogleTranslate

Inspection Detail

Inspection: 906826 - Brown Constructio, Inc.

Inspection Information - Office: Augusta Area Office

 

Inspection Nr: 906826
Report ID: 0111100
Date Opened: 10/09/1985

Site Address:
Brown Constructio, Inc.
1 Cressy Road
Brunswick, ME 04011

Mailing Address:
1 Cressy Road, Brunswick, ME 04011

Union Status: NonUnion

SIC:1541

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/24/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/12/1986


Related Activity
Type Activity Nr Safety Health
Accident 360519003
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 5 9
Current Violations 3 1 5 9
Initial Penalty $700 $0 $100 $0 $0 $800
Current Penalty $275 $0 $25 $0 $0 $300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260303 C03 11/01/1985 11/25/1985 $125 $150 $0 11/26/1985 F - Formal Settlement  
2. 01002 Serious 19260400 C02 11/01/1985 11/04/1985 $50 $300 $0 11/26/1985 F - Formal Settlement  
3. 01003 Serious 19260451 E10 11/01/1985 11/04/1985 $100 $250 $0 11/26/1985 F - Formal Settlement  
4. 02001 Repeat 19260500 D01 11/01/1985 11/04/1985 $25 $100 $0 11/26/1985 F - Formal Settlement  
5. 03001 Other 19260020 B03 11/01/1985 11/25/1985 $0 $0 $0 11/26/1985 -  
6. 03002 Other 19100184 I09 11/01/1985 11/06/1985 $0 $0 $0 11/26/1985 -  
7. 03003 Other 19260251 E01 11/01/1985 11/06/1985 $0 $0 $0 11/26/1985 -  
8. 03004 Other 19260450 A01 11/01/1985 11/06/1985 $0 $0 $0 11/26/1985 -  
9. 03005 Other 19260602 C01 I 11/01/1985 11/06/1985 $0 $0 $0 11/26/1985 -  

Investigation Summary

Investigation Nr: 14477830
Event: 10/09/1985
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU SCAFFOLD

FOUR EMPLOYEES WORKING FROM A TUBULAR WELDED-FRAME MOBILE SCAFFOLD WERE INSTALLING SIDING ON A BUILDING. AS THEY WERE MOVING THE SCAFFOLD AROUND SOME TRANSFORMERS, IT CONTACTED AN OVERHEAD POWER LINE (7200 VOLTS TO GROUND). ONE EMPLOYEE WAS ELECTROCUTED, AND THE THREE OTHERS RECEIVED ELECTRIC SHOCKS BUT WERE NOT HOSPITALIZED.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, MOBILE SCAFFOLD, ELECTROCUTED, E C, ELECTRIC SHOCK, SCAFFOLD, TUBULAR SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 906826 Non Hospitalized injury Electric Shock Occupation not reported
2 906826 Non Hospitalized injury Electric Shock Occupation not reported
3 906826 Fatality Electric Shock Occupation not reported
4 906826 Non Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.