Inspection: 3349669 - Dixon Lumber Company, Inc.

Inspection Information - Office: Va-E-Abingdon (Field Office) - Safety 0355110

 

Inspection Nr: 3349669
Report ID: 0355110
Date Opened: 01/02/1987

Site Address:
Dixon Lumber Company, Inc.
159 Boyer Road
Galax, VA 24333

Mailing Address:
P. O. Box 907, Galax, VA 24333

Union Status: NonUnion

SIC:2426

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/19/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/29/1987


Related Activity
Type Activity Nr Safety Health
Accident 360789150
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $720 $0 $0 $0 $0 $720
Current Penalty $720 $0 $0 $0 $0 $720
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 510001 A 02/26/1987 04/11/1987 $400 $400 $0 03/10/1987 P - Petition to Mod Abatement  
2. 01002A Serious 19100219 D01 02/26/1987 03/02/1987 $320 $320 $0 03/10/1987 W - Empr Withdrew  
3. 01002B Serious 19100219 E03 I 02/26/1987 03/02/1987 $0 $0 $0 03/10/1987 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 14225155
Event: 12/31/1986
EMPLOYEES BURNED BY FLASHBACK WHEN DUST IN BOILER IGNITED

AT APPROXIMATELY 2:30 PM ON DECEMBER 31, 1986, EMPLOYEES #1 AND #2 WERE PREPARING TO START A FIRE IN A BOILER BY INSERTING KINDLING INTO THE FIREBOX. THE TWO EMPLOYEES WERE STANDING IN FRONT OF BOILER #1. APPARENTLY SOME AIRBORNE FINE DUST WAS ENTERING THE FIREBOX WHEN EMPLOYEE #2 INTRODUCED A SOURCE OF IGNITION (A BURNING ROLLED-UP NEWSPAPER) INSIDE THE BOILER. A FLASHBACK OCCURRED, SEVERELY BURNING EMPLOYEES #1 AND #2. A REASONABLE CONCLUSION IS THAT A DUST EXPLOSION OCCURRED BECAUSE OF THE FINE DUST BEING CARRIED INTO THE BOILER BY AIR CURRENTS.

Keywords: BURN, DUST, BOILER, FIRE, EXPLOSION, FLASHBACK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 3349669 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 3349669 Hospitalized injury Burn/Scald(Heat) Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.