Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

Inspection Detail

Inspection: 3270394 - Lloyds Fleet Specialists

Inspection Information - Office: Utah

Nr: 3270394Report ID: 0854910Open Date: 03/25/1985

Lloyds Fleet Specialists
2000 Industrial Circle
Slc, UT 84104
Union Status: NonUnion
SIC: 7532/Top, Body, and Upholstery Repair Shops and Paint Shops

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:03/26/1985
Close Case:07/01/2016

Related Activity:TypeIDSafetyHealth
 Accident360600795    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $240 $0 $0 $0 $0 $240
Current Penalty $240 $0 $0 $0 $0 $240
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001A Serious GEN01340101 03/29/1985 04/15/1985 $120 $120 $0 -
  2. 01001B Serious GEN01340201 03/29/1985 04/15/1985 $0 $0 $0 -
  3. 01001C Serious GEN01340205 03/29/1985 04/15/1985 $0 $0 $0 -
  4. 01001D Serious GEN01340206 03/29/1985 04/15/1985 $0 $0 $0 -
  5. 01002 Serious GEN01060561 03/29/1985 04/15/1985 $120 $120 $0 -
  6. 02001 Other GEN001103 03/29/1985 04/15/1985 $0 $0 $0 -

Accident Investigation Summary
Summary Nr: 14456842Event: 03/22/1985Employee Burned By Fire And Explosion In Fuel Tank
EMPLOYEE #1 WAS PAINTING THE INSIDE OF THE TANK OF A 5,000 GALLON AIRPLANE REFUELING TRUCK. HE WAS SPRAYING A C-36 THERMOGUARD EPOXY COATING WHICH HAS A MINIMUM FLASH POINT OF 36 DEGREES FAHRENHEIT. EMPLOYEE #1 WAS PAINTING WITH A 2-QUART SPRAY GUN AND USING A DROP LIGHT FOR ILLUMINATION WITHIN THE TANK. THE TWO HATCHES ON THE TOP OF THE TANK WERE OPEN, BUT NO MECHANICAL VENTILATION WAS BEING USED. AN UNDETERMINED IGNITION SOURCE IGNITED THE PAINT VAPORS AND A FIRE ERUPTED. EMPLOYEE #1 WAS BURNED OVER 39.5 PERCENT OF HIS BODY (15.5 PERCENT OF THESE BURNS WERE 3RD DEGREE).
Keywords: burn, ventilation, confined space, fire, spray painting, explosion, coating operation, lighting, fuel truck, tank
Inspection Degree Nature Occupation
1 3270394 Hospitalized injury Burn/Scald(Heat) Automobile body and related repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.