Powered by GoogleTranslate

Inspection Detail

Inspection: 3257888 - Forcum-Lannom Associates Inc

Inspection Information - Office: Tennessee Osha Jackson Office - Safety

 

Inspection Nr: 3257888
Report ID: 0454715
Date Opened: 06/27/1985

Site Address:
Forcum-Lannom Associates Inc
Hwy. 78 North
Dyersburg, TN 38024

Mailing Address:
P. O. Box 768, Dyersburg, TN 38024

Union Status: NonUnion

SIC:1542

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/08/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 07/31/1985


Related Activity
Type Activity Nr Safety Health
Accident 360612816
Inspection 3257359
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $560 $0 $0 $0 $0 $560
Current Penalty $560 $0 $0 $0 $0 $560
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260550 A15I 07/16/1985 07/19/1985 $560 $560 $0 -  

Investigation Summary

Investigation Nr: 14214456
Event: 06/27/1985
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU CRANE BOOM

THREE EMPLOYEES WERE IN AN EXCAVATION POURING A FOOTING FROM A CONCRETE BUCKET SUSPENDED FROM A BUCYRUS TELESCOPING CRANE. A FOURTH WAS OPERATING THE CRANE ON THE OPPOSITE BANK OF THE EXCAVATION. AS THE THREE EMPLOYEES IN THE EXCAVATION WERE POSITIONING THE CONCRETE BUCKET, THE ANGLE BRACE ON THE TIP OF THE CRANE CONTACTED A 7650-VOLT OVERHEAD POWER LINE. TWO OF THE EMPLOYEES IN THE EXCAVATION WERE ELECTROCUTED, AND THE THIRD WAS HOSPITALIZED FOR ELECTRIC SHOCK.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, CRANE BOOM, ELECTROCUTED, E C, ELECTRIC SHOCK, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 3257888 Fatality Electric Shock Construction laborers
2 3257888 Fatality Electric Shock Carpenters
3 3257888 Hospitalized injury Electric Shock Concrete and terrazzo finishers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.