Powered by GoogleTranslate

Inspection Detail

Inspection: 317230423 - Edco Waste & Recycling Services

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 317230423
Report ID: 0950632
Date Opened: 12/12/2013

Site Address:
Edco Waste & Recycling Services
6670 Federal Blvd
Lemon Grove, CA 91945

Mailing Address:
6670 Federal Blvd, Lemon Grove, CA 91945

Union Status: NonUnion

SIC:4212

NAICS: 562111/Solid Waste Collection


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/08/2014

Emphasis:

Case Closed: 05/09/2017


Related Activity
Type Activity Nr Safety Health
Accident 101478493
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 2 2 4
Initial Penalty $20,250 $0 $0 $980 $0 $21,230
Current Penalty $15,750 $0 $0 $560 $0 $16,310
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 05/08/2014 06/10/2014 $560 $560 $0 05/28/2014 F - Formal Settlement  
2. 01002 Other 3395 F01 05/08/2014 06/10/2014 $0 $420 $0 05/28/2014 F - Formal Settlement  
3. 02001 Serious 3270 C 05/08/2014 06/10/2014 $9,000 $13,500 $0 05/28/2014 W - Empr Withdrew  
4. 03001 Serious 3650 T07 05/08/2014 06/10/2014 $6,750 $6,750 $0 05/28/2014 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201079928
Event: 11/13/2013
Employee Is Burned by Forklift Radiator Fluid

At approximately 11:30 a.m. on November 13, 2013, Employee #1, with Edco Waste & Recycling Services, was operating a forklift (Linde Lift Truck; Serial Number: H2X393S04578; identified by the employer as FL-3) from approximately 4:00 a.m., moving bales of recyclable paper products from a collection area in the yard into trucks. Then, Employee #1 cleaned and was replacing an air filter on the forklift FL-3. To clean out the air filter, Employee #1 parked FL-3 in the doorway of the maintenance building. The air filter was located on the rear of the forklift, behind the cab frame on the driver's side. Employee #1 removed the air filter and cleaned it out, and then he climbed up onto the back of the forklift to replace it. While up on the back of the forklift, Employee #1's foot dislodged the cooling system radiator cap. The fluid in the lift truck's cooling system was hot and under pressure from being operated all morning. The hot fluid sprayed up and out of the reservoir. Employee #1 was burned on the upper legs and the groin area. Employee #1 jumped off of the back of the forklift onto the ground. Coworkers came to his assistance and called emergency services. Employee #1 was hospitalized at a burn center for over 24 hours, for treatment of second degree burns to the upper legs and groin area.

Keywords: BURN, ABDOMEN, REPAIR, CLEANING, WASTE PROC FAC, INDUSTRIAL TRUCK, PAPER, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 317230423 Hospitalized injury Burn/Scald(Heat) Industrial truck and tractor equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close