Powered by GoogleTranslate

Inspection Detail

Inspection: 316668318 - Gold Coast Tree Service, Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 316668318
Report ID: 0950643
Date Opened: 11/06/2012

Site Address:
Gold Coast Tree Service, Inc.
19853 Horse Shoe Dr.
Topanga Canyon, CA 90290

Mailing Address:
350 E. Easy St., Unit 11, Simi Valley, CA 93065

Union Status: NonUnion

SIC:0783

NAICS: 561730/Landscaping Services


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/05/2013

Emphasis:

Case Closed: 07/29/2013


Related Activity
Type Activity Nr Safety Health
Accident 102784600
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $0 $0 $0 $640 $0 $640
Current Penalty $0 $0 $0 $640 $0 $640
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3395 F01 04/05/2013 05/08/2013 $250 $250 $0 -  
2. 01002 Other 3395 F03 04/05/2013 05/08/2013 $165 $165 $0 -  
3. 01003 Other 5416 A 04/05/2013 04/10/2013 $225 $225 $0 -  

Investigation Summary

Investigation Nr: 202657078
Event: 10/11/2012
Employee Is Burned from Ignited Gasoline Fumes

At approximately 1:00 p.m. on October 11, 2012, Employee #1, groundkeeper, had finished lunch and opened a compartment in a utility truck to place his trash. He was engaged in tree trimming and tree removal activities. A gasoline powered Maruyama blower (Model Number BL8200, Serial Number 80921653) was stored inside the compartment. As he opened the compartment, gasoline vapors ignited within it. His supervisor was approximately 25 ft away when the incident occurred, but did not witness the event. Employee #1 sustained second-degree burns to his face, arms, and hand. He was transported to a medical center, where he underwent burn treatment and was then hospitalized. The cause of the incident was due to insufficient ventilation within the equipment compartment to ensure that the flammable gasoline vapor did not exceed 25 percent of the lower explosive limit.

Keywords: BURN, ENCLOSED SPACE, PORTABLE POWER TOOL, FLAMMABLE VAPORS, ARM, FACE, HAND, TREE TRIMMING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316668318 Hospitalized injury Burn/Scald(Heat) Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close