Powered by GoogleTranslate

Inspection Detail

Inspection: 316620913 - Crown Casting Industries Inc

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 316620913
Report ID: 0454510
Date Opened: 11/16/2012

Site Address:
Crown Casting Industries Inc
108 Corporate Court
Hodges, SC 29653

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3325

NAICS: 331513/Steel Foundries (except Investment)


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/02/2013

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/14/2014


Related Activity
Type Activity Nr Safety Health
Accident 102667607
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $5,000 $0 $0 $0 $0 $5,000
Current Penalty $5,000 $0 $0 $0 $0 $5,000
FTA Penalty $2,400 $0 $0 $0 $0 $2,400

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C01 05/09/2013 07/08/2013 $2,500 $2,500 $2,400 P - Petition to Mod Abatement  
2. 01002 Serious 19100212 A01 05/09/2013 06/11/2013 $2,500 $2,500 $0 -  

Investigation Summary

Investigation Nr: 200376242
Event: 11/15/2012
Employee Suffers Multiple Fractures When Caught by Machine

At approximately 6:41 p.m. on November 15, 2012, Employee #1 was operating a molding machine on the B-Line. The top half of the mold was sent through the mold handler area. Usually when this happens, sand or other debris is on the on the reflectors causing the light beam to be broken. The reflectors have to be cleaned at this point to prevent the machine from sending only the top half of the mold through the area Employee #1 was trying to push the debris through, and became trapped by the push off in the mold handler area of the molding machine. A coworker was working with the employee at the time of the accident, but did not see the accident. The coworker noticed Employee #1 was caught in the machine and went to get the supervisor and called Emergency Medical Service. The supervisor rushed to the machine, raised the 3MPC push off arm, disabled the machine, and kept the employee calm until EMS arrived. When EMS arrived, maintenance cut off all power to machine, braced the push off arm and removed the guard, so EMS could remove Employee #1 from the area. Employee #1 was transported to Greenville Memorial Hospital, where he was treated for fractures to his neck, back, collarbone, and a punctured artery. Employee #1 remains hospitalized.

Keywords: FRACTURE, MOLDING MACHINE, COLLARBONE, CAUGHT BY, BACK, CAUGHT BETWEEN, NECK, ARTERY, PUNCTURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316620913 Hospitalized injury Other Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close