Powered by GoogleTranslate

Inspection Detail

Inspection: 316346824 - V & H Performance, Llc

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 316346824
Report ID: 0950644
Date Opened: 05/01/2013

Site Address:
V & H Performance, Llc
13861 Rosecrans Ave
Santa Fe Springs, CA 90670

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3471

NAICS: 332813/ Electroplating, Plating, Polishing, Anodizing, and Coloring


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/22/2013

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/28/2016


Related Activity
Type Activity Nr Safety Health
Accident 102718145
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $25,000 $0 $0 $1,125 $0 $26,125
Current Penalty $2,000 $0 $0 $119 $0 $2,119
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3314 H 10/22/2013 11/24/2013 $119 $1,125 $0 11/15/2013 F - Formal Settlement  
2. 02001 Serious 3314 D 10/22/2013 11/01/2013 $2,000 $25,000 $0 11/15/2013 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202479218
Event: 04/23/2013
Employee Amputates Finger in Finishing Machine

At approximately 11:10 a.m. on April 22, 2013, Employee #1 was performing a set-up on the End Finishing machine (Number 302, Model Number EF-AC/80, Serial Number:0204EF80c32). The employee placed a tube inside the machine to measure the depth distance, and as he was adjusting the head blades bits. Employee #1 proceeded by placing his left hand on top of the end finisher cylinder head while he activated the manual on/off switch with his right hand. As he activated the switch to the on position, the head cylinder retracted backwards and pinched his left middle finger. Employee #1 was taken by the Safety Manager to an area clinic and later transported to a hand specialist for surgery amputating the tip of his left middle finger. The employee was released after twenty-four hours.

Keywords: AMPUTATED, FINGER, MACHINE OPERATOR, CAUGHT BETWEEN, NIP POINT, BLADE, CYANIDE, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316346824 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close