Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 316344951
Report ID: 0950644
Date Opened: 09/19/2012

Site Address:
Trulite Glass & Aluminum Solutions, Llc
19430 E San Jose Ave
City Of Industry, CA 91748

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3231

NAICS: 327215/Glass Product Manufacturing Made of Purchased Glass


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/17/2013

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/06/2014


Related Activity
Type Activity Nr Safety Health
Accident 102715778
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 3 3 6
Initial Penalty $24,970 $0 $0 $930 $0 $25,900
Current Penalty $2,975 $0 $0 $370 $0 $3,345
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3664 A 01/17/2013 02/03/2013 $0 $325 $0 02/12/2013 F - Formal Settlement  
2. 01002 Other 3650 D 01/17/2013 02/03/2013 $185 $365 $0 02/12/2013 F - Formal Settlement  
3. 01003 Other 3668 F 01/17/2013 02/03/2013 $185 $240 $0 02/12/2013 F - Formal Settlement  
4. 02001 Serious 3704 01/17/2013 01/27/2013 $500 $16,200 $0 02/12/2013 F - Formal Settlement  
5. 03001 Serious 4070 A 01/17/2013 01/27/2013 $2,250 $4,385 $0 02/12/2013 F - Formal Settlement  
6. 04001 Serious 4075 A 01/17/2013 01/27/2013 $225 $4,385 $0 02/12/2013 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202478657
Event: 07/17/2012
Worker Is Pinned by Wooden Case Containing Sheet Glass

At 6:22 a.m. on July 17, 2012, Employee #1 was working for Trulite Glass & Aluminum Solutions LLC in City of Industry, CA. Employee #1 was a permanent employee. The firm fabricated sheet glass and distributed it to the glazing industry. At the facility, sheets of glass were contained in wooden cases and on metal racks. A Hyster 120, Model Number S120XL industrial truck (forklift), with Serial Number D004V09644S, was being used to lift two wooden cases off a truck trailer onto the ground. The wooden cases were secured to these metal racks during transport. The metal racks stood 7.5 feet (2.3 meters) tall from the bed of the truck. The bed of the truck was roughly 4 feet (1.2 meters) from the ground. During the incident, Employee #1 was securing the larger of two wooden cases to the metal racks with straps. The larger case was 7 feet by 10 feet (2.1 meters by 3.0 meters) in size. Employee #1 was between the wooden cases and the opposite metal rack. He was strapping the large wooden case only, when both wooden cases became free from the single strap holding them both to the racks. Employee #1 became pinned between the two wooden cases and the metal racks. He sustained various injuries, including fractured ribs and a liver laceration. The main factor causing the accident was the failure to secure loads against dangerous displacement, especially when workers were in the danger zone. The employer reported the accident to DOSH at 8:30 a.m. on July 18, 2012.

Keywords: FRACTURE, UNSECURED, PINNED, LIVER, INDUSTRIAL TRUCK, LACERATION, MANUAL MAT HANDLING, RIB, FALLING OBJECT, UNSTABLE LOAD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316344951 Hospitalized injury Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.