Powered by GoogleTranslate

Inspection Detail

Inspection: 316343888 - Davis Wire Corporation

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 316343888
Report ID: 0950644
Date Opened: 05/18/2012

Site Address:
Davis Wire Corporation
5555 Irwindale Ave.
Irwindale, CA 91706

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3549

NAICS: 333518/Other Metalworking Machinery Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/26/2012

Emphasis:

Case Closed: 07/15/2013


Related Activity
Type Activity Nr Safety Health
Accident 102715125
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 2 2
Initial Penalty $18,000 $0 $0 $800 $0 $18,800
Current Penalty $0 $0 $0 $7,000 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A02 10/26/2012 11/16/2012 $0 $800 $0 11/19/2012 F - Formal Settlement  
2. 02001 Other 3314 C 10/26/2012 11/16/2012 $7,000 $18,000 $0 11/19/2012 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202478400
Event: 04/29/2012
Employee Amputates Finger in Drive Chain

At around 9:30 p.m. on April 4, 2012, Employee #1, with Davis Wire Corporation, was fixing and adjusting a drive chain that got caught in the gear bearings of index machine (Number 25-04). When he was doing this task, the drive chain suddenly moved. Employee #1's right middle finger was pinched in the chain and sprocket drive resulting in an amputation. About one half in. of top of right middle finger was cut off. Employee #1was taken to the hospital for treatment, and he was released next day. An investigation revealed that the electric power supply (480 - 277 Volts AC) to index machine was de-energized prior to the adjusting task, but the air supply was not. Employee #1 did not bleed the air to the machine prior to the task. Index machine (Number 25-04) worked on a dual power supply system. Employee #1 was trained in lockout tagout rules but did not follow the lockout tagout rules while doing the above task. The employer was cited for not enforcing lockout tagout safety rules in work place, as required by section 3314 (c) and 3203(a)(2) of California Code of Regulations, Title 8.

Keywords: AMPUTATED, FINGER, WORK RULES, LOCKOUT, ELEC CIRC PART--MISC, SPROCKET, DRIVE SHAFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316343888 Hospitalized injury Amputation Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.