Powered by GoogleTranslate

Inspection Detail

Inspection: 316206259 - Ati Allvac

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 316206259
Report ID: 0454510
Date Opened: 06/27/2012

Site Address:
Ati Allvac
4374 Lancaster Highway
Richburg, SC 29729

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3356

NAICS: 331491/ Nonferrous Metal (except Copper and Aluminum) Rolling, Drawing, and Extruding


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 09/21/2012

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 02/12/2013


Related Activity
Type Activity Nr Safety Health
Accident 102667383
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 1 1 2
Initial Penalty $32,500 $0 $0 $0 $0 $32,500
Current Penalty $5,000 $0 $0 $0 $0 $5,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C04 I 10/25/2012 11/27/2012 $4,500 $4,500 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Serious 19100147 C05 I 10/25/2012 11/27/2012 $4,500 $4,500 $0 I - Informal Settlement Citation has been deleted.
3. 01003 Serious 19100147 C07 I 10/25/2012 11/27/2012 $4,500 $4,500 $0 I - Informal Settlement Citation has been deleted.
4. 01004 Serious 19100147 D03 10/25/2012 11/27/2012 $5,000 $5,000 $0 I - Informal Settlement Citation has been deleted.
5. 01005A Serious 10012 A 10/25/2012 11/27/2012 $5,000 $4,500 $0 I - Informal Settlement  
6. 01005B Serious 10012 A 10/25/2012 11/27/2012 $0 $4,500 $0 I - Informal Settlement  
7. 01005C Serious 10012 A 10/25/2012 11/27/2012 $0 $5,000 $0 I - Informal Settlement  
8. 02001 Other 19100147 C06 II 10/25/2012 11/27/2012 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200376119
Event: 06/26/2012
Worker Is Asphyxiated When Cryogenic Box Lid Fails

On June 26, 2012, Employee #1 was working as a heat treat operator at a metal alloy manufacturing facility. He and a coworker, who was also working as a heat treat operator, were monitoring the progress of steel rectangles that were cooling in a cryogenic nitrogen box. The cryogenic nitrogen box was used to supercool metal at a controlled rate. The thermocouple in the back right corner was giving readings outside the acceptable range of 0 to 30 degrees. Employee #1 went out to the nitrogen box to service the thermocouple that was reading approximately minus 40 degrees. The narrative did not state whether these measurements were in degrees Fahrenheit or degrees Celsius. The nitrogen box was constructed of steel and plywood. It had been designed by ATI Allvac in 1998. The nitrogen box was approximately 26 feet in length; 6 feet, 6 inches in width; and 4 feet, 10 inches in height, with the lid closed (7.92 meters long, 1.98 meters wide, and 1.47 meters high). When the lid was open, workers had to step up 17 inches (0.43 meters) into the box. The size of the opening that employees used to enter the box was approximately 26 feet (7.92 meters) in length and 6 feet, 1 inch (1.85 meters) in height. The internal width of the box was approximately 5 feet, 6 inches (1.68 meters). There were a total of seven risers inside the box. Each riser was approximately 10 inches (254 millimeters or 25.4 centimeters) in height. The metal walking surface inside the nitrogen box was icy and slippery, and the area was poorly lit. The nitrogen box's 3,800-pound (1,724-kilogram) lid was lifted by two Hydro-Line single-acting standard pneumatic cylinders on the right and left sides of the box. The cylinders had a 1.375-inch rod diameter, a 40 inch stroke, and a 6 inch bore. (3.5-centimeter rod diameter, 101.6-centimeter stroke, and 15.2-centimeter bore). The pressure of the air going through the flexible air hose was 98 psi (676 kilopascals or 6.76 bar) to105 psi (724 kilopascals to 7.24 bar). The flexible air hose, rated at 200 psi (1,379 kilopascals or 13.79 bar) was attached to a hard line using a brass coupling and an HS10 Dixon worm gear clamp rated for used up to 30 psi (207 kilopascals or 2.07 bar). The brass coupling connecting the hard line to the flexible air hose was rated at 150 psi (1,034 kilopascals or 10.34 bar). According to the manufacturer, the worm gear clamp was not adequate to hold the hose in place at a pressure of 98 psi (676 kilopascals or 6.76 bar). Employee #1 went inside the nitrogen box to reposition and secure the thermocouple. Employee #1 did not engage the safety arms while adjusting the thermocouples on the steel rectangles inside the box. As Employee #1 was inside the box, the hose clamp failed, and the lid closed. Employee #1 was asphyxiated due to nitrogen inhalation, according to the coroner. Secondary injuries were related to extreme cold, but they were not the cause of death. Two maintenance workers found Employee #1 30 minutes to 1 hour after the incident had occurred. There were four violations of OSHA standards related to the accident. Citations were also issued for not developing machine-specific lockout procedures and for not engaging the safety arms. An additional citation was issued for failing to install locking pins or other mechanisms to secure the lid of the nitrogen box in place. A final citation was issued for not training employees on the procedures for isolating the nitrogen box.

Keywords: MAINTENANCE, ASPHYXIATED, CONFINED SPACE, METAL SHOP, TOXIC ATMOSPHERE, INHALATION, EQUIPMENT FAILURE, LINE CONNECTOR, LOCKOUT, NITROGEN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316206259 Fatality Asphyxia Heat treating equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close