Inspection: 316176403 - Western Precooling Systems, Inc.

Inspection Information - Office: Arizona Phoenix Sfty

Nr: 316176403Report ID: 0950411Open Date: 12/05/2011

Western Precooling Systems, Inc.
4139 E Gila Ridge Road
Yuma, AZ 85365
Union Status: NonUnion
SIC: 7623/Refrigeration and Air-Conditioning Service and Repair Shops
NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Mailing: Po Box 5083, Oxnard, CA 93030

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Health Close Conference:12/05/2011
Close Case:06/03/2016

Related Activity:TypeIDSafetyHealth
 Accident101996437    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 5 1 6
Initial Penalty $20,300 $49,000 $0 $0 $0 $69,300
Current Penalty $20,300 $5,000 $0 $0 $0 $25,300
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001A Willful 19100119 C02 05/11/2012 06/04/2012 $5,000 $49,000 $0 06/08/2012 F - Formal Settlement
  2. 01001B Serious 19100119 E01 05/11/2012 06/04/2012 $0 $0 $0 06/08/2012 F - Formal Settlement
  3. 02001A Serious 19100038 C02 05/11/2012 06/04/2012 $3,500 $3,500 $0 06/08/2012 F - Formal Settlement
  4. 02001B Serious 19100038 F03 05/11/2012 06/04/2012 $0 $0 $0 06/08/2012 F - Formal Settlement
  5. 02002 Serious 19100119 F03 05/11/2012 06/04/2012 $3,500 $3,500 $0 06/08/2012 F - Formal Settlement
  6. 02003A Serious 19100119 H02 I 05/11/2012 06/04/2012 $3,500 $3,500 $0 06/08/2012 F - Formal Settlement
  7. 02003B Serious 19100119 H02 II 05/11/2012 06/04/2012 $0 $0 $0 06/08/2012 F - Formal Settlement
  8. 02003C Serious 19100119 H02 IV 05/11/2012 06/04/2012 $0 $0 $0 06/08/2012 F - Formal Settlement
  9. 02004 Serious 19100119 I01 05/11/2012 06/04/2012 $4,900 $4,900 $0 06/08/2012 F - Formal Settlement
  10. 02005 Serious 19100119 L01 05/11/2012 06/04/2012 $4,900 $4,900 $0 06/08/2012 F - Formal Settlement

Accident Investigation Summary
Summary Nr: 202561346Event: 12/02/2011Employee Burned From Condenser Rupture
Employee #1 was near a cooling condenser on a truck mounted ammonia refrigeration compressor trailer. The condenser overpressurized and ruptured, consequently, Employee #1 suffered chemical burns from liquid anhydrous ammonia. Employee #1 was hospitalized for the burns due to this accident.
Keywords: burn, ammonia, rupture, truck
Inspection Degree Nature Occupation
1 316176403 Hospitalized injury Burn(Chemical) Mechanical engineering technicians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.