Powered by GoogleTranslate

Inspection Detail

Inspection: 315347302 - Eagle Burgmann Ejs

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 315347302
Report ID: 0950632
Date Opened: 01/14/2013

Site Address:
Eagle Burgmann Ejs
8575 Roland Acres Rd
Santee, CA 92071

Mailing Address:
10035 Prospect Avenue Ste 202, Santee, CA 92071

Union Status: NonUnion

SIC:3498

NAICS: 332996/Fabricated Pipe and Pipe Fitting Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/17/2013

Emphasis:

Case Closed: 05/23/2016


Related Activity
Type Activity Nr Safety Health
Accident 101473908
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 6 6
Initial Penalty $0 $0 $0 $7,185 $0 $7,185
Current Penalty $0 $0 $0 $6,115 $0 $6,115
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 04/17/2013 05/20/2013 $5,000 $5,000 $0 05/02/2013 F - Formal Settlement  
2. 01002 Other 3203 A 04/17/2013 05/20/2013 $375 $485 $0 05/02/2013 F - Formal Settlement  
3. 01003 Other 3383 A 04/17/2013 05/20/2013 $185 $485 $0 05/02/2013 F - Formal Settlement  
4. 01004 Other 3384 A 04/17/2013 05/20/2013 $185 $485 $0 05/02/2013 F - Formal Settlement  
5. 01005 Other 5144 K05 04/17/2013 05/20/2013 $185 $365 $0 05/02/2013 F - Formal Settlement  
6. 01006 Other 6151 G02 04/17/2013 05/20/2013 $185 $365 $0 05/02/2013 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201078896
Event: 10/17/2012
Air Arching Burns Employee

At approximately 9:00 a.m. on October 17, 2012, Employee #1, of EagleBurgmann EJS, was performing air arcing in the outdoor assembly area at the plant located at 8575 Roland Acres Drive, Santee, CA when he was burned by sparks from the air arcing. The sparks came up under his shirt and caught his shirt on fire. When the employee realized his shirt was burning he used his hand to put out the flames. Employee #1 was not wearing gloves, welding leathers, or any other PPE that would have provided torso, body, or hand protection. The employee was taken to US Healthworks for second-degree burns to his left torso and hand, and was later transferred to UCSD for further treatment. Employee #1 remains hospitalized.

Keywords: BURN, COMPRESSOR, FIRE, TORSO, SPARK, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315347302 Hospitalized injury Burn/Scald(Heat) Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.