Inspection Detail
Inspection: 315320085 - Abel Mendoza, Inc
Inspection Information - Office: Oakland District Office
Site Address:
Abel Mendoza, Inc
9309 Tesla Rd
Livermore, CA 94550
Mailing Address:
24711 S. Chrisman Rd, Tracy, CA 95304
Union Status: NonUnion
SIC:7361
NAICS: 561310/Employment Placement Agencies
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/12/2012
Emphasis:
Case Closed: 12/14/2012
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361585912 |
Investigation Summary
On November 5, 2012, Employee #1 was ripping and cutting a wooden section on a table circular saw. There was no safety guard at the circular's saw point of operation. The circular saw blade was also rotating at 3,600 rpm. As he manually feed the stock to the blade, the wooden piece became stuck on the slots of the table. He decided to disengage the wood. While releasing the wood, the fingers of his left hand contacted the saw blade. The blade partially amputated one finger and lacerated two other fingers on his left hand. Employee #1 was admitted to a orthopedic clinic, where he was treated, hospitalized and then discharged.
Keywords: AMPUTATED, FINGER, STRUCK AGAINST, JAMMED, LACERATION, BLADE, UNGUARDED, TABLE SAW
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 315320085 | Hospitalized injury | Amputation | Laborers, except construction |