Inspection Detail
Inspection: 314990342 - Lodi Iron Works Inc
Inspection Information - Office: Modesto District Office
Site Address:
Lodi Iron Works Inc
820 S Sacramento St
Lodi, CA 95240
Mailing Address:
Po Box 1150, Lodi, CA 95240
Union Status: NonUnion
SIC:3441
NAICS: 332312/Fabricated Structural Metal Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/13/2011
Emphasis:
Case Closed: 06/03/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102570256 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $0 | $0 | $0 | $1,100 | $0 | $1,100 |
| Current Penalty | $0 | $0 | $0 | $1,100 | $0 | $1,100 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A04 | 04/14/2011 | 05/31/2011 | $550 | $550 | $0 | - | ||
| 2. | 01002 | Other | 3303 | 04/14/2011 | 05/31/2011 | $550 | $550 | $0 | - |
Investigation Summary
Employee #1 was adding metal into a furnace for melting, and was spattered by molten metal. The metal that was introduced into the furnace had moisture on it, which reacted to the molten metal that was in the furnace. Employee #1 suffered burns to his back, and was treated and released from the hospital.
Keywords: BURN, FURNACE, BACK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 314990342 | Non Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction |
Translate