Inspection: 314858648 - National Technical Systems Inc

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 314858648
Report ID: 0950641
Date Opened: 01/25/2011

Site Address:
National Technical Systems Inc
5320 W. 104th St.
Los Angeles, CA 90045

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:8734

NAICS: 541380/Testing Laboratories


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/18/2011

Emphasis:

Case Closed: 05/14/2011


Related Activity
Type Activity Nr Safety Health
Accident 102581097
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $280 $0 $280
Current Penalty $0 $0 $0 $280 $0 $280
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A07 D 04/19/2011 06/03/2011 $280 $280 $0 -  

Investigation Summary

Investigation Nr: 202542668
Event: 01/18/2011
Employee Suffers Fractures after Falling Off A-Frame Ladder

On January 18, 2011 Employee #1 started working on that day at 12:00 a.m. and the accident occurred at 7:00 a.m.. The thermal test in chamber C-7 required several days to complete, and the accident occurred on the second day of the test. Liquid nitrogen was used to cool parts inside chamber to -300 F degrees, and a heater inside the chamber to heat parts to +300 F degrees. Prior to the accident occurring, Employee #1 observed some nitrogen gas leak from the top of chamber, and all 3 clamps at the top of chamber were not secured down. After confirming with the test engineer to bring chamber back to room temperature, and all 3 clamps needed to be secure at the top; Employee #1 used 8 foot A-frame ladder to access clamps at the top of chamber. Employee #1 fell off ladder while he was standing on the 6th rung of ladder. Employee #1 did not remember anything about the accident and why he fell. There were no actual witnesses to the accident. Employee #1 was taken to Centinela Hospital and was hospitalized for 3 days. Employee #1 suffered broken right wrist and shoulder pain.

Keywords: FRACTURE, SHOULDER, LADDER, FALL, WRIST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314858648 Hospitalized injury Fracture Engineering technicians, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.