Inspection Detail
Inspection: 314754979 - Kermanig Inc
Inspection Information - Office: High Hazard Unit - South
Site Address:
Kermanig Inc
1373 E Colorado St
Glendale, CA 91205
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2051
NAICS: 311812/Commercial Bakeries
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/17/2011
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/13/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101694743 |
Investigation Summary
At approximately 1:00 p.m. around March 5, 2009, Employee #1 was cleaning the Lawrence Equipment Adamatic Divider Rounder (Model Number 0DR0006-02 and Serial Number DR 233). Employee #1 sustained injuries including a bent finger and scars on the index and middle fingers. The nature of the event or injuries wwas not specified in the original narrative. Employee #1 was employed by Kermanig, Incorporated, a commercial bakery that produced breads and pastries which are shipped to retail stores for sale. The cause of the accident was the Lock Out Tag Out procedures were not followed and the employer failed to guard the machine and enforce the Lock Out Tag Out.
Keywords: FINGER, GUARD, CLEANING, FORMING MACHINE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 314754979 | Non Hospitalized injury | Fracture | Bakers |