Inspection Detail
Inspection: 314425034 - Ferrellgas
Inspection Information - Office: Dosh Seattle Service Location, Seattle, Wa
Site Address:
Ferrellgas
3611 A Street Se
Auburn, WA 98002
Mailing Address:
Attn Risk Management 1 Liberty Plaza, Liberty, MO 64068
Union Status: NonUnion
SIC:5172
NAICS: 424720/Petroleum and Petroleum Products Merchant Wholesalers (except Bulk Stations and Terminals)
Inspection Type: Accident
Scope: Complete
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 09/22/2010
Emphasis: L:Wasafety
Case Closed: 12/22/2010
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102369659 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 2 | 5 | |||
Current Violations | 3 | 2 | 5 | |||
Initial Penalty | $8,400 | $0 | $0 | $0 | $0 | $8,400 |
Current Penalty | $8,400 | $0 | $0 | $0 | $0 | $8,400 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 0240096003 A 02 | 11/12/2010 | 05/26/2010 | $3,900 | $3,900 | $0 | - | ||
2. | 01001B | Serious | 0240097501 | 11/12/2010 | 12/15/2010 | $0 | $0 | $0 | - | ||
3. | 01001C | Serious | 0242401903 | 11/12/2010 | 12/15/2010 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
4. | 01002 | Serious | 024009700201 | 11/12/2010 | 12/15/2010 | $2,700 | $2,700 | $0 | - | ||
5. | 01003 | Serious | 8001605501 | 11/12/2010 | 05/26/2010 | $1,800 | $1,800 | $0 | - | ||
6. | 02001 | Other | 0242400302 | 11/12/2010 | 05/26/2010 | $0 | $0 | $0 | - | ||
7. | 02002 | Other | 0242400705 | 11/12/2010 | 12/15/2010 | $0 | $0 | $0 | P - Petition to Mod Abatement |
Investigation Summary
On May 26, 2010, Employee's #1 and #2 were setting propane tanks and taking inventory in a tank storage yard. They were electrocuted and killed when the boom of their Simon-Ro boom truck made contact with a 7,200 volt power line.
Keywords: BOOM TRUCK, OVERHEAD POWER LINE, BOOM, ELECTROCUTED, PROPANE, TANK
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 314425034 | Fatality | Electric Shock | Occupation not reported | ||