Powered by GoogleTranslate

Inspection Detail

Inspection: 313878415 - Tridelta Systems, Llc

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 313878415
Report ID: 0419700
Date Opened: 09/04/2010

Site Address:
Tridelta Systems, Llc
5299 Alabama Street
Graceville, FL 32440

Mailing Address:
P.O. Box 356, Abbeville, AL 36310

Union Status: NonUnion

SIC:7699

NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance


Inspection Type: Unprog Rel

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 09/29/2010

Emphasis: S:Struck-By

Case Closed: 01/19/2011


Related Activity
Type Activity Nr Safety Health
Accident 101358133
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $0 $0 $0 $1,800 $0 $1,800
Current Penalty $0 $0 $0 $1,800 $0 $1,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19040032 B02 II 12/14/2010 12/17/2010 $600 $600 $0 -  
2. 01002 Other 19040032 B02 II 12/14/2010 12/17/2010 $600 $600 $0 -  
3. 01003 Other 19040032 B02 II 12/14/2010 12/17/2010 $600 $600 $0 -  

Investigation Summary

Investigation Nr: 201354081
Event: 09/03/2010
Employee Is Crushed by Conveyor Gate

On September 3, 2010, Employee #1, a welder, was welding on the DDM log selector gate at the Rex Lumber sawmill. This gate was part of a conveyor system for logs. When the logs approached the gate on the conveyor system, the gate pneumatically closed if the log was large enough to trigger the gate. The large log was then conveyed to another part of the conveyor system behind the gate. If a log was not large enough to trigger the gate, the gate remained open, and the smaller log was dropped through the gate to be conveyed to another part of the conveyor system. Portions of this gate had become damaged and needed to be repaired. The DDM Wave Feeder and the Reception Belt conveyor system were deenergized and locked out. The DDM Edger Chipper Multifunction line operators control panel was being used to maintain the log selector gate in an open position. The Log Selection Gate control switch was placed in the "AUTO" position on the control booth console. This provided a compressed air energy source which was holding the Log Selector Gate OPEN while Employee #1 was welding on the trough of the machine where the logs drop down onto the reception belt. There were two safety chains attached to the side of the machine. These chains were used to hold the gate open in case the facility lost electrical power, which would cause the Log Selector Gate to lose compressed air and the gate would close. A coworker entered the DDM operators control booth to turn off some Log Accumulation Deck chain conveyors which were left running by the day shift. When the coworker turned the Log Accumulation deck chains control switch to the OFF position, the Log Selector Gate closed immediately, crushing Employee #1. The coworker was not aware the Log Accumulation Deck chains were interconnected to the Log Selector Gate machine. Employee #1 sustained blunt force injuries to the chest and abdomen, and died on the site.

Keywords: LOG, WELDER, LOCKOUT, CAUGHT BETWEEN, CRUSHED, CONVEYOR, SAWMILL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313878415 Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close