Powered by GoogleTranslate

Inspection Detail

Inspection: 313639734 - Key Energy Services California Inc

Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - Central

 

Inspection Nr: 313639734
Report ID: 0950664
Date Opened: 02/17/2010

Site Address:
Key Energy Services California Inc
Occidental Of Elk Hills
Bakersfield, CA 93309

Mailing Address:
5080 California Ave #150, Bakersfield, CA 93309

Union Status: NonUnion

SIC:1389

NAICS: 213112/Support Activities for Oil and Gas Operations


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/03/2010

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/28/2012


Related Activity
Type Activity Nr Safety Health
Accident 362460271
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 1 1 2
Initial Penalty $49,500 $0 $0 $0 $0 $49,500
Current Penalty $13,500 $0 $0 $7,000 $0 $20,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3203 A07 D 08/03/2010 08/21/2010 $0 $13,500 $0 08/23/2010 D - Govt Dismissed Citation has been deleted.
2. 02001 Serious 3203 A07 F 08/03/2010 08/21/2011 $0 $9,000 $0 08/23/2010 D - Govt Dismissed Citation has been deleted.
3. 03001 Other 6624 A 08/03/2010 08/21/2010 $7,000 $13,500 $0 08/23/2010 F - Formal Settlement  
4. 04001 Serious 6535 A 08/03/2010 08/21/2010 $13,500 $13,500 $0 08/23/2010 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202530036
Event: 02/15/2010
Four Employees Are Injured in Oil Well Explosion

At 9:27 p.m. on Monday, February 15, 2010, the second shift five employee oil workover rig crew removed the master valve and then inspected the tubing hanger locking screws and packing glands at an Occidental of Elk Hills, Well Number 627-13Z. High pressure from the well casing bore lifted the 70,700-pound hanger string releasing high pressure gas to the atmosphere. Two of the ELCO ET Style Lock Screws were not removed or installed according to the manufacture instructions & procedure and the Lock Screw Pins did not engage and secure the tubing hanger casing it to lift from the well casing bore flange. The pressure blast injured Employee #1, #2, #3, and #4, who were working at the well head. Employee #1, #2, and #3 were hospitalized for more than 24 hours with broken right legs and related leg injuries. Employee #4 was treated and released for an injured ear drum. The incident was reported to DOSH at 1:33 a.m. on February 16, 2010.

Keywords: FRACTURE, EAR, EXPLOSION, HIGH PRESSURE, VALVE, BLOWOUT--OIL WELL, WELLHEAD, OIL RIG, PRESSURE RELEASE, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313639734 Hospitalized injury Fracture Drilling and boring machine operators
2 313639734 Hospitalized injury Fracture Drilling and boring machine operators
3 313639734 Hospitalized injury Fracture Drilling and boring machine operators
4 313639734 Non Hospitalized injury Other Drilling and boring machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.