Inspection Detail
Inspection: 313509937 - Searles Valley Minerals
Inspection Information - Office: San Bernardino District Office
Site Address:
Searles Valley Minerals
13200 Main Street
Trona, CA 93562
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:1474
NAICS: 212391/ Potash, Soda, and Borate Mineral Mining
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/08/2010
Emphasis:
Case Closed: 02/11/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102612819 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $400 | $0 | $400 |
| Current Penalty | $0 | $0 | $0 | $400 | $0 | $400 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3310 A | 12/08/2010 | 12/13/2010 | $400 | $400 | $0 | - |
Investigation Summary
At approximately 3:20 p.m., on June 9, 2010, Employee #1 of Searles Valley Minerals, received first and second degree burns to chest, abdomen and right arm, when the bleeder valve on the discharge pipe was opened and the hot ESP Solution (Circuit Wash Water) sprayed onto his body. Employee #1 had gone over to help Employee #2 get the flow back up on the second ESP Disslover Pump. Upon washing the suction piping out, Employee #1 and Employee #2 primed the pump and brought it back up. Employee #1 then opened the bleeder valve on the discharge piping on #2 Dissolver Pump to check if the pump was flowing. When Employee #1 opened the bleeder valve, the discharge of the line was facing away from Employee #1. The discharge line spun around and pointed directly at Employee #1 and Employee #2. Employee #1 was hit with the hot ESP Solution (Circuit Wash Water and ESP fine) in the right side of his upper torso and at the lower part of his bicep on his right Arm. Employee #2 who was standing behind Employee #1 at the time of the incident, saw what was happening and got out of the way as quickly as he could. The majority of the hot water was blocked by Employee #1, who was standing in front of Employee #2. Employee #1 was hospitalized for one week at Grossman Burn Center, Bakersfield, Ca.
Keywords: BURN, TORSO, ARM, WATER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 313509937 | Hospitalized injury | Burn/Scald(Heat) | Miscellaneous plant and system operators |