Powered by GoogleTranslate

Inspection Detail

Inspection: 313509143 - Dunn'S Designer Pools

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 313509143
Report ID: 0950633
Date Opened: 06/17/2010

Site Address:
Dunn'S Designer Pools
71375 Cholla Way
Palm Desert, CA 92260

Mailing Address:
74866 Lennon Place #A, Palm Desert, CA 92260

Union Status: NonUnion

SIC:1799

NAICS: 238990/All Other Specialty Trade Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/02/2010

Emphasis:

Case Closed: 01/19/2012


Related Activity
Type Activity Nr Safety Health
Accident 102612736
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4 8
Current Violations 1 7 8
Initial Penalty $10,800 $0 $0 $1,600 $0 $12,400
Current Penalty $2,700 $0 $0 $2,800 $0 $5,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 B01 12/02/2010 01/04/2011 $400 $400 $0 -  
2. 01002 Other 5157 C01 12/02/2010 01/04/2011 $400 $400 $0 -  
3. 01003 Other 5157 C02 12/02/2010 01/04/2011 $400 $400 $0 -  
4. 01004 Other 5157 C04 12/02/2010 01/04/2011 $400 $400 $0 -  
5. 02001 Serious 5157 D05 A 12/02/2010 12/10/2010 $2,700 $2,700 $0 12/13/2010 F - Formal Settlement  
6. 03001 Other 5157 D05 B 12/02/2010 12/10/2010 $400 $2,700 $0 12/13/2010 F - Formal Settlement  
7. 04001 Other 5157 D06 12/02/2010 12/10/2010 $400 $2,700 $0 12/13/2010 F - Formal Settlement  
8. 05001 Other 5157 G01 12/02/2010 12/10/2010 $400 $2,700 $0 12/13/2010 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202655056
Event: 06/02/2010
Employee Suffers Burns When Heater Explodes

At Approximately 7:30 AM, an employee (EE#1) of Dunn's Designer Pool sustained 2nd and 3rd degree burns to 51of his body that included the chest, back and both legs. An employer representative for Dunn's Designer Poolreported this accident to the San Bernardino District Office on the same day at 8:45 AM. Dunn's Designer Pool is a pool contractor. EE#1 went into an underground vault to bleed a line leading to the heater. The heater warms up the water in the spa. EE#1 after bleeding the line he exit the underground vault to check the water in the spa to make sure that it was heating up. EE#1 then went back and entered the underground fault to turn off the valve for the heater. EE#1 then began exiting the underground fault when there was an explosion. EE#1's body was half way out the vault when an explosion occurred. The explosion threw EE#1 approximately five feet into the air causing EE#1 to land on the steel grate (opening) of the underground vault. EE#1 right leg was hanging in the vault when he landed. The cause of this accident was the employer did not test conditions in the permit space to determine if acceptable entry conditions exist before entry is authorize to begin.

Keywords: BURN, ELECTRICAL VAULT, ELECTRICAL, EXPLOSION, WATER HEATER, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313509143 Hospitalized injury Burn/Scald(Heat) Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.