Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 313507022 - Atlantic Plant Maintenance Inc

Inspection Information - Office: Ca San Bernardino

Nr: 313507022Report ID: 0950633Open Date: 11/24/2009

Atlantic Plant Maintenance Inc
2492 West San Bernardino Avenue
Redlands, CA 92374
Union Status: Union
SIC: 7699/Repair Shops and Related Services, Not Elsewhere Classified
NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Mailing: 3861 Bricket Court, Ceres, CA 95304

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:03/08/2010
Close Case:02/11/2011

Related Activity:TypeIDSafetyHealth
 Accident102610110    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $5,000 $0 $5,000
Current Penalty $0 $0 $0 $1,500 $0 $1,500
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Other 342 A 03/08/2010 04/08/2010 $1,500 $5,000 $0 04/26/2010 F - Formal Settlement

Accident Investigation Summary
Summary Nr: 202601241Event: 10/09/2009Dropped Liner Cap Crushes Electrical Workers Finger
At approximately 12:01 a.m., On October 09, 2009, Employee #1, a Journeyman millwright and a regular employee at the Atlantic Plant Maintenance, Inc., was working at the Mountain View Power Generation Station- Turbine unit number 3B, San Bernardino, Redlands, CA, owned & operated by Southern California Edison. Employee #1 was manually installing liner caps (weighing 150-pounds, part of the turbine combustion systems) with the assistance of a coworker. During installation, liner cap got stuck and crooked due to it not being level. Both employees were trying to lift the liner cap for alignment, when it suddenly became free and dropped. Employee #1's gloved left index finger got pinched between the cap & the liner and he sustained a serious crushing injury to the left index finger tip. A supervisor drove Employee #1 to the Redlands Community Hospital for treatment, where an X-ray was taken. He was given appointment for surgery at Arrowhead Regional Medical Center in Colton, CA on October 12, 2009. Surgery was performed on an out patient basis.
Keywords: electrical, finger, electrician, electrical work, crushed
Inspection Degree Nature Occupation
1 313507022 Non Hospitalized injury Amputation Millwrights

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close