Inspection Detail
Inspection: 313388134 - Asplundh Const Dba Asplundh Electrical Const
Inspection Information - Office: Bakersfield District Office
Site Address:
Asplundh Const Dba Asplundh Electrical Const
Caliente Rd & Bodfish Rd
Bodfish, CA 93290
Mailing Address:
11135 Knott Ave Suite F, Cypress, CA 90630
Union Status: Union
SIC:1623
NAICS: 237130/Power and Communication Line and Related Structures Construction
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/04/2013
Emphasis: S:Construction (Cship)
Case Closed: 05/06/2013
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102627197 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | ||||||
Initial Penalty | $18,000 | $0 | $0 | $0 | $0 | $18,000 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 3210 B | 04/08/2013 | 04/18/2013 | $0 | $18,000 | $0 | 05/06/2013 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
At approximately 4:30 p.m. on November 20, 2012, Employee #1, a 51-year-old male journey lineman with Asplundh Construction Dba Asplundh Electrical Construction was exiting the bucket of a truck mounted aerial bucket truck. Employee #1 used his hand to grab the hand bracket near the bucket, and went to place his foot on the step near the bucket. While Employee #1 was climbing down, his foot did not make good contact with the step, causing him to lose his grip on the hand hold, and fall from the top of the tool box mounted on the bed of the truck to the ground below. Employee #1 received unspecified fracture injuries when he fell from a height in excess of 40 in. Employee #1 was on an Altec Bucket Truck that was mounted on a three axle truck chassis. The vehicle did not have guardrails around the bed of the truck so that the linemen could hold onto when exiting the bucket. The employer was a high voltage power line construction and maintenance company that provided services to power companies.
Keywords: FRACTURE, ELECTRICIAN, ELECTRICAL WORK, FALL, AERIAL LIFT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 313388134 | Hospitalized injury | Fracture | Occupation not reported |